No Detail Found!

Electromagnetic Navigation in Distal Locking of Long Diaphyseal Interlocking Intramedullary Nailing.

Author(s)
Zhentao Zhou Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, China
Xiaozhong Zhou Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, China
Bingchen Shan Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, China
Haibin Zhou Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, China
Zhengfeng Lu Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, China
Qirong Dong Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, China
Abstract
Objective: To describe the applications and effects of electromagnetic navigation (EN) technology in distal locking for the treatment of long diaphyseal fracture (LDF) with interlocking intramedullary nailing (IIN). Study Design: An interventional study. Place and Duration of Study: The Second Affiliated Hospital of Soochow University, China, from March 2013 to July 2014. Methodology: Patients who underwent IIN-LDF were selected. Twenty-four (50%) of whom were operated under EN guidance (group A) and the other 24 (50%) under conventional targeting guidance (group B). The distal locking time and X-ray irradiation time of the two groups were compared. Results: Each group included 16 (33.3%) cases of femoral fracture and 8 (16.7%) cases of tibial fracture. The success rate of distal locking in group A was higher than that in group B (95.8% vs. 83.3%, p=0.045). There were statistically significant differences in the distal locking time and X-ray irradiation time of femoral intramedullary nailing between the two groups (p=0.027 and p=0.001, respectively). There were no statistically significant differences in the distal locking time and X-ray irradiation time of tibial intramedullary nailing between the two groups (p=0.347 and p=0.056, respectively). Conclusion: EN-IN was advantageous as it enabled easy targeting, significantly reduced intraoperative fluoroscopy and operation time and small trauma and had other advantages when used for treating LDFs, especially femoral diaphyseal fractures.
Publication Details
Page(s) 975-979
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 26, Issue: 12, Year: 2016

Request the full text from PASTIC

References
RicciWM,GallagherB,HaidukewychGJ, 2009.Intramedullary nailing of femoral shaft fractures: Current concepts,J Am Acad Orthop Surg 17 296 -305
JankovicA,KoracZ,BozicNB,StedulI., 2013.Influence of knee flexion and atraumatic mobilisation of infrapatellar fat pad on incidence and severity of anterior knee pain after tibial nailing,Injury 44 S33 -9
Hernández-VaqueroD,Suárez-VázquezA,Iglesias-FernándezS,García-GarcíaJ,Cervero-SuárezJ, 2012.Dynamisation and early weight-bearing in tibial reamed intramedullary nailing: Its safety and effect on fracture union,Injury 43 S63 -7
RamosL,BertrandML,Benitez-ParejoN,GueradoE, 2012.How many distal bolts should be used in unreamed intramedullary nailing for diaphyseal tibial fractures,Injury 43 S59 -S62
MarcusMS,YoonRS,LangfordJ,KubiakEN,MorrisAJ,KovalKJ, 2013.Is there a role for intramedullary nails in the treatment of simple pilon fractures? Rationale and preliminary results,Injury 44 1107 -11
IkpemeI,NgimN,UdosenA,OnubaO,EnembeO,BelloS., 2011.External jig-aided intramedullary interlocking nailing of diaphyseal fractures: Experience from a tropical developing centre,Int Orthop 35 107 -11
VeenEJ,EttemaHB,ZuurmondRG,MostertAK, 2011.Are there any advantages in using a distal aiming device for tibial nailing? Comparing the centro nailing system with the unreamed tibia nail,Injury 42 1049 -52
ArlettazY,DominguezA,FarronA,EhlingerM,MoorBK, 2012.Distal locking of femoral nails: Evaluation of a new radiationindependent targeting system,J Orthop Trauma 26 633 -7
SoniRK,MehtaSM,AwasthiB,SinghJL,KumarA,ThakurL, 2012.Radiation-free insertion of distal interlocking screw in tibial and femur nailing: A simple technique,J Surg Tech Case Rep 4 15 -8
NegrinLL,VécseiV.,Is, 2013.a magnetic-manual targeting device an appealing alternative for distal locking of tibial intramedullary nails?,Arch Trauma Res 2 16 -20
RohillaR,SinghR,RohillaS,MaguNK,DevganA,SiwachR, 2011.Locked intramedullary femoral nailing without fracture table or image intensifier,Strategies Trauma Limb Reconstr 6 127 -35
WhatlingGM,NokesLD, 2006.Literature review of current techniques for the insertion of distal screws into intramedullary locking nails,Injury 37 109 -19
AgarwalA, 2011.Radiation risk in orthopedic surgery: Ways to protect yourself and the patient,Opera Techn Sport Med 19 220 -3
UzoigweCE,MiddletonRG, 2012.Occupational radiation exposure and pregnancy in orthopaedics,J Bone Joint Surg Br 94 23 -7
GiordanoBD,GrauerJN,MillerCP,MorganTL,RechtineGR, 2011.Radiation exposure issues in orthopaedics,J Bone Joint Surg Am 93 e69 -
LangfittMK,HalvorsonJJ,ScottAT,SmithBP,RussellGB,JinnahRH, 2013.Distal locking using an electromagnetic fieldguided computer-based real-time system for orthopaedic trauma patients,J Orthop Trauma 27 367 -72
AnastopoulosG,NtagiopoulosPG,ChissasD,LoupasisG,AsimakopoulosA,AthanaselisE, 2008.Evaluation of the Stryker S2 IM nail distal targeting device for reduction of radiation exposure: A case series study,Injury 39 1210 -5
DurakbasaO,HaklarU,TuygunH,TürkmenM., 2002.Intramedullary nailing of adult femoral fractures,Acta Orthop Traumatol Turc 36 316 -21
ImGI,ShinSR, 2002.Treatment of femoral shaft fractures with a titanium intramedullary nail,Clin Orthop 401 223 -9
ChouLB,CoxCA,TungJJ,HarrisAH,Brooks-TerrellD,SiehW., 2010.Prevalence of cancer in female orthopaedic surgeons in the United States,J Bone Joint Surg Am 92 240 -4
HoffmannM,SchröderM,LehmannW,KammalM,RuegerJM,Herrman Ruecker, 2012.A. Next generation distal locking for intramedullary nails using an electromagnetic X-ray-radiationfree real-time navigation system,J Trauma Acute Care Surg 73 243 -8
HoffmannM,HartelM,SchroederM,ReinschO,SpiroAS,RueckerAH, 2014.Electromagnetic navigation provides high accuracy for transcoracoid-transclavicular drilling,Knee Surg Sports Traumatol Arthrosc 22 2237 -42
MoreschiniO,PetrucciV,CannataR, 2014.Insertion of distal locking screws of tibial intramedullary nails: A comparison between the free-hand technique and the SURESHOT™ distal targeting System,Injury 45 405 -7
0

Citations

0

Downloads

67

Views