No Detail Found!

Characterisation of 100 µm diameter shape memory alloy actuators for cyclic applications.

Author(s)
J. DAUDPOTO Department of Mechanical Engineering, MUET, Jamshoro, Pakistan
A. F. ABBASI Department of Mechanical Engineering, MUET, Jamshoro, Pakistan
S. A. SHAH Department of Mechanical Engineering, MUCET, Khairpur Mirs Sindh, Pakistan
Abstract
In this paper, the actuation behaviour of two commercially available shape memory alloy (SMA) actuators known as Flexinol and Biometal both having diameter of 100μm is investigated under cyclic loading conditions. An experimental test rig was used to characterize the Nickel-Titanium (NiTi) based SMA actuators. Three different actuation voltages, 4.5 V, 5 V, 5.5 V, were used. The length of stroke and drift over one hundred cycles were measured for both types of actuators. The results showed that a higher actuation voltage result in higher length of stroke. Similarly, larger drift was observed for higher voltages. It was also found from the experimental results that Biometal actuators underwent larger drift than Flexinol actuators, this showed weaker resistance to permanent deformation for the former. It has been found from this research that Flexional actuators having diameters of 100μm produced larger stroke and smaller drift than Biometal actuators under similar cyclic actuation conditions.
Publication Details
Page(s) 647-649
DOI DOI not available
Published Journal: Sindh University Research Journal, Volume: 45, Issue: 3, Year: 2013

Request the full text from PASTIC

0

Citations

0

Downloads

31

Views