Percutaneous Closure of Patent Ductus Arteriosus under Echocardiographic Guidance.

Author(s)
Muhammad Arif Khan Department of Pediatric Cardiology, King Salman Heart Center, King Fahad Medical City, Riyadh, Saudi Arabia
Milad ElSegaier Department of Pediatric Cardiology, King Salman Heart Center, King Fahad Medical City, Riyadh, Saudi Arabia
Mohammed Omar Galal Department of Pediatric Cardiology, King Salman Heart Center, King Fahad Medical City, Riyadh, Saudi Arabia
Abstract
Percutaneous closure of patent ductus arteriosus (PDA) is done in the cardiac catheterization laboratory, usually under fluoroscopic and angiographic guidance. The aortogram is used for assessing PDA size and shape the pre-device implantation. Additionally, post-device aortograms are applied for the assessment of device position, profile and residual shunt. Angiograms expose patient to radiation and possible untoward effects of contrast media. Recently, transthoracic echocardiography has been utilized to guide in PDA closure to avoid radiation exposure as well as contrast material. On two occasions, we were obligated by special circumstances to close the PDA under echocardiography guidance. First case was a 6-month baby girl with mild signs of heart failure having moderate size PDA. She underwent device closure under transthoracic echocardiogram as the angiographic system had stopped working during the procedure. Second case was a 6-year girl, weighting 16-kg with chronic renal failure. She had moderate size PDA closed by device under transthoracic echocardiographic, guidance avoiding the use of contrast agent due to chronic renal failure.
Publication Details
Page(s) 533-535
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 26, Issue: 6, Year: 2016

Request the full text from PASTIC

Keywords
Patent ductus arteriosus. Echocardiography guidance. Interventional closure. Radiation
References
GalalMO,HussainA,ArfiA, 2006.Do we still need the surgeon to close the persistently patent arterial duct?,Cardiol Young 16 522 -36
LiangCD,KoSF,HuangSC, 2003.Echocardiographic guidance for transcatheter coil occlusion of patent ductus arteriosus in the catheterization laboratory,J Am Soc Echocardiogr 16 476 -9
MageeAG,HuggonIC,SeedPT,QureshiSA,TynanM, 2001.Association for European Cardiology: Transcatheter coil occlusion of the arterial duct; results of the European Registry,Eur Heart J 22 1817 -21
BaruteauAE,HascoetS,BaruteauJ,BoudjemlineY,LambertV,AngelCY, .Transcatheter closure of patent ductus arteriosus: past, present and future,Arch Cardiovasc Dis. -
ThomasBartel,SilvanaMuller, 2011.Device closure of patent ductus arteriosus: optimal guidance by transaortic phased-array imaging,Eur J Echocardiograph 12 E9 -
ChenL,ChengZ,ChenD, 2013.Comparison of transvenous versus transthoracic catheter-based device closure of patent ductus arteriosus with amplatzer duct occluder,J Invasive Cardiol 25 502 -6
BaruteauaAE,HascoëtcS,BaruteauJ,BoudjemlineY,LambertV,AngelCY, 2014.Transcatheter closure of patent ductus arteriosus: Past, present and future,Arch Cardiovas Dis 107 122 -32
BaykanA,NarinN,ÖzyurtA,ArgunM,PamukçuÖ,OnanSH, 2015.Do we need a femoral artery route for transvenous PDA closure in children with ADO-I?,Anatol J Cardiol 15 242 -7
0

Citations

0

Downloads

87

Views