No Detail Found!

Microbiological Load of Ethylene Oxide Sterilized Medical Devices and its Elimination by Cobalt 60 Source.

Author(s)
Rasheeda Bashir Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan
Bakht Afroze Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan
Hafiza Fizza Zulfiqar Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan
Resham Saleem Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan
Imran Altaf WTO, Quality Operational Laboratory (QOL), University of Veterinary and Animal Sciences, Lahore, Pakistan
Faiza Saleem Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan
Farheen Aslam Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan
Shagufta Naz Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan
Abstract
Objective: To determine the residing microbial flora of ethylene oxide (EtO) sterilized medical devices and optimization of safe dose of gamma radiation (Cobalt 60 source) for the complete elimination of microbial load. Study Design: Experimental study. Place and Duration of Study: Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan from September 2014 to June 2015. Methodology: Thirty-six samples of EtO sterilized medical devices of same batch of three different companies were collected for this study. Isolation and enumeration of microbes were done by using different selective and differential media. Gram staining and biochemically characterization by API 20 (Bio Merieux, France) kit was done for identification of the microorganisms. The medical devices having high microbial load were sent to Pakistan Radiation Services (PARAS) for gamma irradiations at 3 different selected doses (20 KGy, 25 KGy, and 30 KGy). Results: Different types of Gram positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus and Bacillus subtilis) were isolated from the EtO sterilized samples. Gram negative bacteria and fungi were not detected on these medical devices. Gamma irradiations results showed that 30 KGy was optimized dose for complete elimination of microbial flora on endotracheal, Nelaton, and tracheostomy tubes. Conclusion: Gamma radiations (Co 60 source) effectively decontaminate the microbial flora on the equipment previously sterilized by the ethylene oxide gas; and 30 KGy is the optimized dose for all these medical devices.
Publication Details
Page(s) 486-489
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 26, Issue: 6, Year: 2016

Request the full text from PASTIC

References
MendesGCC,BrandaoTRS,SilvaCLM, 2007.Ethylene oxide sterilization of medical devices: a review,Am J Infect Control 35 574 -81
AllegranziB,PittetD, 2007.Healthcare-associated infection in developing countries: simple solutions to meet complex challenges,Infect Control Hosp Epidemiol 28 1323 -7
EzriT,EvronS,HadadH,RothY., 2005.Tracheostomy and endotracheal intubation: a short history,Harefuah 144 891 -3
ShaikhJM,DevrajaniBR,ShahSZ,AkhundT,BibiI, 2008.Frequency, pattern and etiology of nosocomial infection in intensive care unit: an experience at a tertiary care hospital,J Ayub Med Coll Abbottabad 20 37 -40
DruckerE,AlcabesPG,MarxPA, 2001.The injection century: massive unsterile injections and the emergence of human pathogens,Lancet Infect Dis 358 1989 -92
DarwisD,AbbasBE,NurlidarF,PutraDP, 2015.Radiation processing of polymers for medical and pharmaceutical applications,Macromol Symp 353 15 -23
CBEEmbrarad. Tecnologia, 2010., -
DaSilva Aquino,KA, 2012.Sterilization by gamma irradiation, -
AkhtarN., 2010.Hospital acquired infections in a medical intensive care unit,J Coll Physicians Surg Pak 20 386 -90
LambertBJ,MendelsonTA,CravenMD, 2011.Radiation and ethylene oxide terminal sterilization experiences with drug eluting stent products,AAPS Pharm Sci Tech 12 1116 -26
DonlanRM, 2001.Biofilms and device: Associated infections,Emerg Infect Dis 7 277 -81
HugonnetS,SaxH,EggimannP, 2004.Nosocomial blood stream infection and clinical sepsis,Emerg Infect Dis 10 76 -81
Von EiffC,PetersG,HeilmannC, 2002.Pathogenesis of infections due to coagulase-negative Staphylococci,Lancet Infect Dis 2 677 -85
KubyshkinaG,MarionL,EmriI., 2012.The influence of different sterilization techniques on the time-dependent behavior of polyamides,J Biomat Nanobiotech 2 361 -
Abo-StateMA,El-GamalMS,El-DanasoryA,MabroukMA, 2014.Radio-impact of gamma radiation on pathogenic bacterial strains isolated from Rosetta branch and its drains of river Nile water,Mid East J Sci Res 21 776 -81
KhurshidSJ,WaqarA,MalikIA, 1993.Radiation sterilization of medical products and its potential,Pak J Pathol 4 142 -
0

Citations

0

Downloads

135

Views