No Detail Found!

Routine use of Glidescope and Macintosh Laryngoscope by Trainee Anesthetists.

Author(s)
Mansoor Aqil Department of Anesthesiology, King Saud University, King Khalid University Hospital, Riyadh, Saudi Arabia
Mueen Ullah Khan Department of Anesthesiology, King Saud University, King Khalid University Hospital, Riyadh, Saudi Arabia
Altaf Hussain Department of Anesthesiology, King Saud University, King Khalid University Hospital, Riyadh, Saudi Arabia
Rashid Saeed Khokhar College of Medicine, King Saud University, Riyadh, Saudi Arabi; King Khalid University Hospital, Riyadh, Saudi Arabia; Department of Anesthesiology, King Saud University, King Khalid University Hospital, Riyadh, Saudi Arabia
Saara Mansoor Alfaisal University, Riyadh, Saudi Arabia
Tariq Alzahrani Department of Anesthesiology, King Saud University, King Khalid University Hospital, Riyadh, Saudi Arabia
Abstract
Objective: To compare intubating conditions, success rate, and ease of intubation by anesthesia trainees using Glidescope Videolaryngoscope (GVL) compared to Macintosh laryngoscope (MCL). Study Design: Comparative study. Place and Duration of Study: King Khalid University Hospital, Riyadh, Saudi Arabia, from January 2012 to February 2015. Methodology: Eighty adult patients ASA I and II with normal airway, scheduled to undergo elective surgery requiring endotracheal (ET) intubation were enrolled. Patients were randomly divided into 2 groups: GVL and MCL. All intubations were performed by trainee residents having experience of more than 1 year and who had successfully performed more than 50 tracheal intubations with each device. Glottic view based on Cormack and Lehane's (C&L's) score and percentage of glottis opening (POGO) score, time to successful intubation, need of external pressure, and overall difficulty scores were compared using either GVL or MCL. Results: View of glottis based on C&L's classification was better (p < 0.001) and POGO score was higher (88.25 ±22.06 vs. 57.25 ±29.26, p < 0.001) with GVL compared to MCL. Time to intubate in seconds was (32.90 ±8.69 vs. 41.33 ±15.29, p = 0.004) and overall difficulty score was less 2.78 ±1.39 vs. 4.85 ±1.75 (p < 0.001) using GVL compared to MCL. Conclusion: Residents found ET intubation to be faster and easier with superior glottic view using GVL compared to MCL in patients with normal airway.
Publication Details
Page(s) 245-249
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 26, Issue: 4, Year: 2016

Request the full text from PASTIC

References
MalikMA,MaharajCH,HarteBH,LaffeyJG, 2008.Comparison of Macintosh, Truview EVO2, Glidescope, and airwayscope laryngoscope use in patients with cervical spine immobilization,Br J Anaesth 101 723 -30
StanleyGD, 2009.Is it time for a Glidescope letter?,Anesthesiology 111 1391 -
AzizMF,HealyD,KheterpalS,FuRF,DillmanD,BrambrinkAM, 2011.Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions,Anesthesiology 114 34 -41
Sharma D. Is, 2010.Glidescope the best way to intubate?,Anesthesiology 113 258 -9
ChoiGS,LeeEH,LimCS,YoonSH, 2011.A comparative study on the usefulness of the Glidescope or Macintosh laryngoscope when intubating normal airways,Korean J Anesthesiol 60 339 -43
IbinsonJW,EzaruCS,CormicanDS,MangioneMP, 2014.Glidescope Use improves intubation success rates: an observational study using propensity score matching,BMC Anesthesiol 14 101 -
Nouruzi-SedehP,SchumannM,Groeben H, 2009.Laryngoscopy via Macintosh blade versus Glidescope: success rate and time for endotracheal intubation in untrained medical personnel,Anesthesiology 110 32 -7
LangleyA,MarFan G, 2014.Comparison of the Glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study,BMC Anesthesiol 14 10 -
HendersonJJ,PopatMT,LattoIP,PearceAC, 2004.Difficult Airway Society guidelines for management of the unanticipated difficult intubation,Anaesthesia 59 675 -94
LiliX,ZhiyongH,Jianjun S, 2014.A comparison of the Glidescope with the Macintosh laryngoscope for nasotracheal intubation in patients with ankylosing spondylitis,J Neurosurg Anesthesiol 26 27 -31
MaharajCH,BuckleyE,HarteBH,LaffeyJG, 2007.Endotracheal intubation in patients with cervical spine immobilization: a comparison of macintosh and airtraq laryngoscopes,Anesthesiology 107 53 -9
CortellazziP,CaldiroliD,ByrneA,SommarivaA,OrenaEF,TramacereI, 2015.Defining and developing expertise in tracheal intubation using a Glidescope® for anaesthetists with expertise in Macintosh direct laryngoscopy: an in-vivo longitudinal study,Anaesthesia 70 290 -5
KaplanMB,HagbergCA,WardDS,BrambrinkA,ChhibberAK,HeideggerT, 2006.Comparison of direct and videoassisted views of the larynx during routine intubation,J Clin Anesth 18 357 -62
KimHJ,ChungSP,ParkIC,ChoJ,LeeHS,ParkYS, .Comparison of the Glidescope video laryngoscope and, -
HsiaoWT,LinYH,WuHS,ChenCL, 2005.Does a new videolaryngoscope (Glidescope) provide better glottic exposure?,Acta Anaesthesiol Taiwan 43 147 -51
XueFS,ZhangGH,LiuJ,LiXY,YangQY,XuYC, 2007.The clinical assessment of Glidescope in orotracheal intubation under general anesthesia,Minerva Anestesiol 73 451 -7
SerockiG,BeinB,ScholzJ,DörgesV, 2010.Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the Glidescope,Eur J Anaesthesiol 27 24 -30
SchumannM,BörgersA,PförtnerR,MohrC,Groeben H, 2014.Tracheal intubation in patients with odentogenous abscesses and reduced mouth opening,Br J Anaesth 112 348 -54
AndersenLH,RovsingL,OlsenKS, 2011.Glidescope videolaryngoscope vs. Macintosh direct laryngoscope for intubation of morbidly obese patients: a randomized trial,Acta Anaesthesiol Scand 55 1090 -7
WangPK,HuangCC,LeeY,ChenTY,LaiHY, 2013.Comparison of 3 video laryngoscopes with the Macintosh in a manikin with easy and difficult simulated airways,Am J Emerg Med 31 330 -8
SunDA,WarrinerCB,ParsonsDG,KleinR,UmedalyHS,MoultM., 2005.The Glidescope video laryngoscope: randomized clinical trial in 200 patients,Br J Anaesth 94 381 -4
MansoorAqil, 2014.A study of stress response to endotracheal intubation comparing Glidescope and flexible fiberoptic bronchoscope,Pak J Med Sci 30 1001 -6
JonesPM,TurkstraTP,ArmstrongKP,ArmstrongPM,CherryRA,HoogstraJ, 2007.Effect of stylet angulation and endotracheal tube camber on time to intubation with the Glidescope,Can J Anaesth 54 21 -7
DoyleDA, 2005.The Glidescope video laryngoscope,Anaesthesia 60 414 -5
KimJT,NaHS,BaeJY,KimDW,KimHS,KimCS, 2008.Glidescope video laryngoscope: a randomized clinical trial in 203 paediatric patients,Br J Anaesth 101 531 -4
LeeJH,ParkYH,ByonHJ,HanWK,KimHS,KimCS, 2013.A comparative trial of the Glidescope(R) video laryngoscope to direct laryngoscope in children with difficult direct laryngoscopy and an evaluation of the effect of blade size,Anesth Analg 117 176 -81
0

Citations

0

Downloads

60

Views