No Detail Found!

Diffusion-weighted MR Imaging and ADC Mapping in Differentiating Benign from Malignant Thyroid Nodules.

Author(s)
AyeshaT Khizer Department of Radiology, Combined Military Hospital (CMH), Lahore, Pakistan
Saleem Raza Department of Radiology, Combined Military Hospital (CMH), Rawalpindi, Pakistan
Atiqur Rehman Slehria Department of Radiology, Combined Military Hospital (CMH), Lahore, Pakistan
Abstract
Objective: To determine the diagnostic accuracy of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) mapping in differentiating benign from malignant thyroid nodules by taking histopathology as the gold standard. Study Design: A cross-sectional analytical study. Place and Duration of Study: Department of Radiology at Combined Military Hospital (CMH), Lahore, from August 2012 to July 2013. Methodology: Thirty-five patients, who were referred to radiology department of CMH, Lahore, for ultrasound or Fine Needle Aspiration Cytology (FNAC) of thyroid gland, fulfilling the inclusion and exclusion criteria, were included in the study. They were evaluated on 1.5 Tesla MRI machine with T1- and T2-weighted imaging as well as fat-suppressed technique. DWI was done using b-values of 0 and 1000 s/mm2 and ADC values were calculated for the thyroid nodules. All of these patients were subjected to ultrasound guided core biopsy and histopathology results were correlated with ADC values. Results: The benign nodules showed facilitated diffusion while malignant nodules showed restricted diffusion. T-test was used to assess the difference in mean ADC values between benign and malignant nodules. The mean ADC value of the malignant thyroid nodules (0.94 ±0.16 x 10-3 mm2/s) was significantly lower than that of the benign thyroid nodules (1.93 ±0.13 x 10-3 mm2/s) (p-value < 0.05). ADC value of 1.6 x 10-3 mm2/s was used as a cut-off, for differentiating benign from malignant thyroid nodules. The sensitivity, specificity, PPV, NPV and diagnostic accuracy of DWI and ADC values in differentiating benign from malignant thyroid nodules were 93%, 95%, 93%, 95% and 92.3%, respectively. Conclusion: DWI is a non-invasive diagnostic tool for characterization and differentiation between benign and malignant thyroid nodules. It not only decreases the burden of unnecessary surgeries when pre-operative FNAC and biopsy are inconclusive, but is also helpful in reaching a definite diagnosis when a nodule is not amendable to biopsy due to any reason.
Publication Details
Page(s) 785-788
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 25, Issue: 11, Year: 2015

Request the full text from PASTIC

References
., -
MaharSA,HusainA,IslamN., 2006.Fine needle aspiration cytology of thyroid nodule: diagnostic accuracy and pitfalls,J Ayub Med Coll Abottabad 18 26 -9
ErdemG,ErdemT,KarakasHM,MutluD,FıratAK,SahinI, 2010.Diffusion-weighted images differentiate benign from malignant thyroid nodules,J Magn Reson Imaging 31 94 -100
MortensenJD,WoolnerLB,BennettWA, 1955.Gross and microscopic findings in clinically normal thyroid glands,J Clin Endocrinol Metab 15 1270 -
ShahSH,MuzaffarS,SoomroIN, 1999.Morphological patterns and frequency of thyroid tumors,J Pak Med Assoc 49 131 -3
ZuberiLM,YawarA,IslamN,JabbarA., 2004.Clinical presentation of thyroid cancer patients in Pakistan - AKUH experience,J Pak Med Assoc 54 526 -
Schueller-WeidekammC,KasererK,SchuellerG,ScheubaC,RinglH,WeberM, 2009.Can quantitative diffusion-weighted MR imaging differentiate benign and malignant cold thyroid nodules? Initial results in 25 patients,Am J Neuroradiol 30 417 -22
Charles-EdwardsEM,deSouzaNM, 2006.Diffusion-weighted magnetic resonance imaging and its application to cancer,Cancer Imaging 6 135 -43
BozgeyikZ,CoskunS,DagliAF,OzkanY,Sahpaz F, 2009.Diffusionweighted MR imaging of thyroid nodules,Neuroradiology 51 193 -8
WangJ,TakashimaS,TakayamaF,KawakamiS,SaitoA,MatsushitaT, 2001.Head and neck lesions: characterization with diffusion-weighted echo-planar MR imaging,Radiology 220 621 -30
El-HaririMA,GouharGK,SaidNS,RiadMM, 2012.Role of diffusionweighted imaging with ADC mapping and in vivo 1H-MR spectroscopy in thyroid nodules,Egyptian J Radiol Nuclear Med 43 183 -92
Le BihanD,BretonE,LallemandD,AubinML,VignaudJ,Laval-JeantetM, 1988.Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging,Radiology 168 497 -505
SpuentrupE,BueckerA,AdamG,van VaalsJJ,GuentherRW, 2001.Diffusion-weighted MR imaging for differentiation of benign fracture edema and tumor infiltration of the vertebral body,Am J Roentgenol 176 351 -5
ColograndeS,CarboneSF,CarusiLM,CovaM,VillariN., 2006.Magnetic resonance diffusion-weighted imaging: extraneurological applications,Radiol Med 111 392 -419
0

Citations

0

Downloads

70

Views