No Detail Found!

Comparison of Efficacy of Carbon Dioxide (CO) Laser with Cutting 2 Diathermy in Surgical Excision of Early Carcinoma Tongue.

Author(s)
Muhammad Rashid Department of ENT, Combined Military Hospital (CMH), Lahore, Pakistan
Muhammad Ali Hashmi Department of ENT, Combined Military Hospital (CMH), Lahore, Pakistan
Shahzad Maqbool Department of ENT, Combined Military Hospital (CMH), Lahore, Pakistan
Majid Dastigir Department of ENT, Combined Military Hospital (CMH), Lahore, Pakistan
Abstract
Objective: To compare the efficacy of carbon dioxide (CO2) laser with cutting diathermy as a cutting device in surgical excision of early carcinoma tongue. Study Design: Experimental study. Place and Duration of Study: Combined Military Hospital (CMH), Rawalpindi and CMH, Lahore, from July 2008 to July 2011. Methodology: Twenty two biopsy proven cases of T1 and early T2 squamous cell carcinoma of tongue were divided in two equal groups of 11 each labeled as A and B. Tumor was excised by CO2 laser in group A while cutting diathermy was done in group B. For both groups tumor excision time, per-operative blood loss, postoperative oral swelling and pain was recorded. Excision time of tumor was assessed in minutes and amount of blood loss in milliliters till complete hemostasis after removal of primary tumor. Postoperatively patients were assessed on 12 hourly basis for 48 hours for pain. Pain was analyzed on visual analogue score 1 - 10. Oral swelling was assessed once after 24 hours and labeled as mild, moderate and severe. Independent sample t-test was applied for analysis of excision time, postoperative pain and per-operative blood loss for both groups. Postoperative swelling was analyzed using Fisher's exact test. P-value of < 0.05 was considered significant. Results: The mean age at diagnosis in group A was 49.36 ± 5.27 years, while in group B patients had mean age of 50.73 ± 8.13 years. In group A, 4/11 (36.3%) patients were having tumor stage T1 while 7/11 (63.6%) had T2 stage tumor. In group B, 5/11 (45.4%) were having T1 and 6/11 (54.5%) were having stage T2 tumor. Excision time was significantly shorter for group B (p=0.003), but group A had less postoperative pain (p=0.001), less per-operative blood loss (p=0.001) and less postoperative oral swelling (p=0.021). Conclusion: Early carcinoma tongue is better removed by laser than electrocautery in terms of postoperative morbidity, per-operative blood loss, postoperative pain and oral swelling.
Publication Details
Page(s) 747-751
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 25, Issue: 10, Year: 2015

Request the full text from PASTIC

References
ParkinDM,BrayF,FerlayJ,PisaniP, 2005.,2002. CA Cancer J Clin 55 74 -108
StewartBW,KleihuesP, 2003.,World cancer report -
KhanM,DinQ,SalamA, 2007.Niswar as a risk factor in the etiology of oral cancer,J Pak Dent Assoc 16 77 -81
NajeebT., 2006.Clinic pathological presentation of tongue cancers and early cancer treatment,J Coll Physicians Surg Pak 16 179 -82
AsifM,MuzafarK., 2000.The carcinoma tongue - incidence risk factors, presentation and treatment,J Coll Physicians Surg Pak 10 454 -7
BrayF,SankilaR,FerlayJ,ParkinDM, 2002.Estimates of cancer incidence and mortality in Europe in 1995,Euro J Cancer 38 99 -166
SchantzSP,YuGP, 2002.Head and neck cancer incidence trends in young Americans, 1973-1997, with a special analysis for tongue cancer,Arch Otolaryngol Head Neck Surg 128 268 -74
WangCF,ChangSY,WuJD,TaiSK, 2001.Carbon dioxide laser microsurgery for tongue cancer: surgical techniques and longterm results,J Otolaryngol 30 19 -23
SpiroRH,StrongEW, 1974.Surgical treatment of cancer of the tongue,Surg Clin North Am 54 759 -65
WernerJA,DünneAA,FolzBJ,LippertBM, 2002.Transoral laser microsurgery in carcinomas of the oral cavity,Pharynx, and Larynx Cancer Control 9 379 -86
RanaM,IqbalA,WarraichR,RueckerM,EckardtAM,GellirichNC, 2011.Modern surgical management of tongue carcinoma: a clinical retrospective research over a 12 years period,Head Neck Oncol 3 43 -
PanjeWR,ScherN,KarnellM., 1989.Transoral carbon dioxide laser ablation for cancer, tumors, and other diseases,Arch Otolaryngol Head Neck Surg 115 681 -8
PinheiroAB,FrameJW, 1994.An audit of CO2 laser surgery in mouth,Braz Dent J 5 15 -25
MalikAM,AhmedZ,BashirU, 2005.Immediate tissue response comparison of wound after partial glossectomy by 3 watt, 6 watt CO2 laser and scalpel,Ann Pak Inst Med Sci 1 220 -6
BasuMK,FrameJW, 1988.Wound healing following partial glossectomy using the CO2 laser, diathermy and scalpel: a histological study in rats,J Laryngol Otol 102 322 -7
BellinaJH,HemmingsR,VorosJI,RossLF, 1984.Carbon dioxide laser and electrosurgical wound study with an animal model: a comparison of tissue damage and healing patterns in peritoneal tissue,Am J Obstet Gynecol 148 327 -34
AprilAC,GuyJP,FundakowskiC, 2008.Transoral laser excision of base of tongue cancer,Oto-HNS 139 47 -
GottschlichS,AmbroschP, 2004.Laser microsurgery of oral cavity cancer,Oper Tech Otolaryngol - HNS 15 252 -5
LaranneJ,MatsuneS,ShimaT,OhyamaM., 1996.Histological changes in elastic components of soft palate scars after CO2 and contact Nd:YAG laser incisions in the dog as an experimental model,Euro Arch Otorhinolaryngol 253 454 -9
HiranoM,OhkuboH,KuritaS,MaedaT,KamimuraM,KawaguchiT, 1985.CO2 laser in treating carcinoma of the tongue,Auris Nasus Larynx 12 S10 -4
Niccoli-FilhoW,Murilo-SantosL,AlineRC,CardosoG,CanellasS., 2011.Surgical treatment of squamous cell carcinoma of tongue with carbon dioxide laser radiation (CO2),J Laser Appl 24 -
LiboonJ,FunkhouserW,Terris DJ, 1997.A comparison of mucosal incisions made by scalpel, CO2 laser, electrocautery, and constant-voltage electrocautery,Otolaryngol Head Neck Surg 116 379 -85
SchneiderD,FidlerJ,SchroderT,BendichP,WesselerT,SchellhasF, 1986.Comparison of wound healing between the superpulse CO2 laser, electrosurgical knife and steel knife incisions,Lasers Surg Med 6 546 -51
BryantGL,DavidsonJM,OssoffRH,GarrettCG,ReinischL, 1998.Histologic study of oral mucosa wound healing: a comparison of a 6.0 to 6.8 micrometer pulsed laser and a carbon dioxide laser,Laryngoscope 108 13 -7
0

Citations

0

Downloads

52

Views