Elective use of high frequency oscillatory ventilation with transcutaneous carbon dioxide monitoring during thoracoscopic diaphragmatic hernia repair.

Author(s)
Michelle Leriger Department of Anesthesiology & Pain Medicine, Nationwide Children’s Hospital, Columbus, Ohio, USA
Arlyne Thung Department of Anesthesiology & Pain Medicine, Nationwide Children’s Hospital, Columbus, Ohio, USA
Karen Diefenbach Department of Pediatric Surgery, Nationwide Children’s Hospital, Columbus, Ohio, USA
Edward Shepherd Division of Neonatology and Department of Pediatrics, Nationwide Children’s Hospital, Columbus, Ohio, USA
Erin Wishloff Neonatal Respiratory Services, Nationwide Children’s Hospital, Columbus, Ohio, USA
Joseph D. Tobias Department of Anesthesiology & Pain Medicine, Nationwide Children’s Hospital, Columbus, Ohio, USA
Abstract
Thoracoscopy, a minimally invasive technique, for congenital diaphragmatic hernia (CDH) repair has been shown to offer significant advantages versus open procedures. However, positive pressure ventilation during thoracoscopy can be challenging. Minimizing lung movement is important to improve surgical visualization, but one-lung ventilation can be difficult in neonates and infants. Ventilation-perfusion inequalities occur in the lateral decubitus position making it challenging to maintain oxygenation and control hypercarbia from carbon dioxide insufflation. High frequency oscillatory ventilation (HFOV) offers an alternative means of ventilation for such cases. It maintains a constant distending pressure for the alveoli and optimal lung volumes while limiting peak inflating pressures and thus lung over distention. This provides a means of ensuring adequate oxygenation and ventilation with minimal lung movement, allowing adequate intraoperative exposure. During HFOV, continuous monitoring of carbon dioxide (CO2) can be problematic as end-tidal technology is not feasible. As such, we used transcutaneous CO2 (PtcCO2) monitoring in our patient. We present the elective intraoperative institution of HFOV with PtcCO2 monitoring in a 4-day-old infant for thoracoscopic repair of CDH. Previous reports regarding the intraoperative use of HFOV are reviewed and its application in this scenario is discussed. The utility of continuous PtcCO2 monitoring during such cases is presented.
Publication Details
Page(s) 287-292
DOI DOI not available
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 16, Issue: 3, Year: 2012