No Detail Found!

Can Transcutaneous Carbon Dioxide and Oxygen Pressure Predict Arterial Carbon Dioxide and Oxygen Pressure during Laparoscopic Bariatric Surgery?.

Author(s)
Tomoki Nishiyama Department of Anesthesiology, Harada Hospital, 1-13-3, Toyooka, Iruma, Saitama, 358-0003, Japan
Abstract
Objective: In bariatric surgery, arterial carbon dioxide (PaCO2) and oxygen (PaO2) pressures are important but sometimes difficult to measure. The purpose of the present study was to investigate whether transcutaneous carbon dioxide (tcPCO2) and oxygen (tcPO2) pressures can be used to monitor PaCO2 and PaO2, respectively, in laparoscopic bariatric surgery. Methodology: This non-blind, comparadive study was conducted at operating room in the city hospital. Ten adult obese (Body Mass Index (BMI) > 35) patients for laparoscopic bariatric surgery (Bariatric group), and 10 normal weight (BMI < 30) adult patients for open gastric surgery (Control group) were studied. After an epidural catheter insertion at T6-7 or T 7-8, anesthesia was induced with midazolam, propofol, fentanyl, and vecuronium, and was maintained with continuous propofol and remifentanil, intermittent vecuronium and epidural lidocaine. After anesthesia induction, a radial artery catheter was inserted. The electrode of transcutaneous monitor was put on the chest ipsilateral to a radial artery catheter. Pressure controlled ventilation was used in both groups. During surgery at four random points in each patient samples were drawn for arterial blood gas analysis, and measurements of end-tidal carbon dioxide (EtCO2), tcPO2 and tcPCO2 were performed. Results: TcPCO and PaCO2 in the control group had good correlation, while no correlation was found in the 2 bariatric group. TcPO2 and PaO2, tcPCO2 and EtCO2, and PaCO2 and EtCO2 had no correlation in both groups. The bias and limits of agreement of tcPCO - PaCO2, tcPO2 - PaO2, EtCO2 - tcPCO2, and PaCO2 - EtCO2 were larger in the 2 bariatric group than the control group. Conclusion: Our study concludes that TcPO2 and tcPCO2 cannot be surrogate measurements of PaO2 and PaCO , 2 respectively in laparoscopic bariatric surgery.
Publication Details
Page(s) 131-136
DOI DOI not available
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 20, Issue: 2, Year: 2016

Request the full text from PASTIC

References
2003.,Lancet 361 2001 -2
Scand, 1976., 20 248 -54
1996.,Anaesthesiol Scand 40 191 -200
2003., 91 498 -501
.The application of transcutanelus CO2, -
2014.9:e91563, 10 -
., -
2010., 10 417 -20
0b013e3181e30b54., -
2012.arterial and end-tidal measurements of carbon dioxide during laparoscopic cholecystectomy in patients with chronic obstructive pulmonary disease,J Int Med Res 40 1982 -7
NishiyamaT., 2014.Transcutaneous carbon dioxide and oxygen pressure in laparoscopic surgery,The Internet Journal of Anesthesiology 1 -
NishiyamaT,KohnoY,KoishiK., 2011.Comparison of ear and chest probes in transcutaneous carbon dioxide pressure measurements during general anesthesia in adults,J Clin Monit Comput 10 323 -8
NishiyamaT,NakamuraS,YamashitaK., 2006.Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia,Eur J Anaesthesiol 23 1049 -54
NishiyamaT,NakamuraS,YamashitaK., 2006.Effects of the electrode temperature of a new monitor, TCM4, on the measurement of transcutaneous oxygen and carbon dioxide tension,J Anesth 20 331 -4
RodriguezP,LelloucheF,AboabJ,BuissonBC,BrochardL, 2006.Transcutaneous arterial carbon dioxide pressure monitoring in critically ill adult patients,Intensive Care Med 32 309 -12
KuzutaT,KamideM,KagawaS. Transcutaneous, 2012.PCO2 (TcPCO2) reflects PaCO2 of previous 1 or 2 minutes,Jpn J Anesthesiol 61 638 -42
NyarwayaJB,MazoitJX,SamiiK., 1994.Are pulse oximetry and end-tidal carbon dioxide tension monitoring reliable during laparoscopic surgery,Anaesthesia 49 775 -8
GirardisM,BroiUD,AntonuttoG,PasettoA, 1996.The effect of laparoscopic cholecystectomy on cardiovascular function and pulmonary gas exchange,Anesth Analg 83 134 -40
CuvelierA,GrigoriuB,MolanoLC,MuirJF, 2005.Limitations of transcutaneous carbon dioxide measurements for assessing long-term mechanical ventilation,Chest 127 1744 -8
DionJM,McKeeC,TobiasJD,HerzD,SohnerP,TeichS,MichalskyM., 2015.Carbon dioxide monitoring during laparoscopicassisted bariatric surgery in severely obese patients: transcutaneous versus end-tidal techniques,J Clin Monit Comput 10 183 -6
BernhardtV,LorenzoS,BabbTG,ZavorskyGS, 2013.Corrected end-tidal PCO2 accurately estimates PaCO2 at rest and during exercize in morbidly obese adults,Chest 143 471 -7
NishiguchiBK,YuM,SuetsuguA,JiangC,TakiguchiSA,TakanishiDM, 2008.Determination of reference ranges for transcutaneous oxygen and carbon dioxide tension and the oxygen challenge test in healthy and morbidly obese subjects,J Surg Res 150 204 -11
0

Citations

0

Downloads

33

Views