Comparison of Esmolol and Nitroglycerine on Hemodynamic Parameters during Extubation in Obese Patients Following Laparoscopic Cholecystectomy: a Prospective Randomized Study.

Author(s)
Nupur Chakravorty Department of Anesthesiology, L.N. Medical College & J.K. Hospital, Kolar Rd, Chuna Bhatti, Bhopal, Madhya Pradesh, India
Devashish Chakravarty Department of Anesthesiology, Chirayu Medical College & Hospital, Bhainsakhedi, Bhopal, Madhya Pradesh, India
Rashim Vachhani Department of Anesthesiology, C.M. Medical College, Durg District, Kachandur, Chhattisgarh, India
RV Shidhaye Department of Anesthesiology, C.M. Medical College, Durg District, Kachandur, Chhattisgarh, India
Abstract
Introduction: One of the main concerns for the anesthesiologist in obese hypertensive patients is to prevent hypertension, tachycardia and arrhythmias during extubation, and to ensure an awake patient with full airway control and stable hemodynamics. Our aim was to compare the effects of single bolus of intravenous nitroglycerine and intravenous esmolol on hemodynamic response and quality of extubation following tracheal extubation in obese patients posted for elective laparoscopic surgery. Methodology: 60 ASA PS II and III patients with BMI > 25, undergoing elective laparoscopic cholecystectomy under general anesthesia were randomly divided into two groups: Group E (n=30) received esmolol 2 mg/kg intravenously; Group N (n=30) received nitroglycerine 2 µg/kg before extubation. Heart rate (HR), systolic, diastolic and mean arterial pressures were recorded at time of discontinuation of isoflurane (T0), at time of reversal (T1), before (T2) and after (T3) extubation, 3 min (T4) and 5 min (T5) postextubation. Statistical analysis was done using Stata 11 software. For continuous variables, mean and standard deviations were compared using unpaired t-test. For categorical data chi-square test was applied. For comparison of scores two-sample Wilcoxon rank-sum (Mann-Whitney) test was used. P-value 0.05) and T4 (67.23 ± 8.68 vs 90.03±8.27, p < 0.01). Maximum percentage decline in HR (19.22%) in Group E was seen at T4 compared to T0. Systolic blood pressure was significantly low compared to Group N at T2 (148.9 ± 8.66 vs 155.7 ± 14.81, p < 0.05), T3 (131.9 ± 8.91 vs 137.9 ± 8.86, p < 0.01 and T4 (127.56 ± 9.01 vs 135.63 ± 9.71, p < 0.01). Rate pressure product was significantly lower in Group E at T2, T3 and T4 as compared to Group N. Maximum percentage decline in rate pressure product (23.38%) in Group E was seen at T4 when compared to T0. No significant difference was observed in sedation score, time to extubation or quality of extubation. Conclusion: Administration of nitroglycerine and esmolol intravenously prior to extubation in obese hypertensive patients is a practical and safe method to ensure stable hemodynamics with good patient awakening and airway control during extubation. Esmolol has a significantly better effect in controlling rate pressure product.
Publication Details
Page(s) 437-443
DOI DOI not available
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 19, Issue: 4, Year: 2015

Request the full text from PASTIC

References
MillerKA,HarkinCP,BaileyPL, .Postoperative tracheal extubation,Anesth 80 149 -72
StoneJG,FoexP,SearJW,JohnsonLL,KhambattaHJ,TrinerL, 1988.Risk of myocardial ischemia during anaesthesia in treated and untreated patients,Br J Anaesth 61 675 -679
EdwardsND,AlfordAM,DobsonPM,PeacockJE,ReillyCS, 1994.Myocardial ischaemia during tracheal intubation and extubation,Br J Anaesth 73 537 -9
MikawaK,NishinaK,TakaoY,ShigaM,MaekawaN, 1997.ObaraH. Attenuation of cardiovascular responses to tracheal extubation: Comparison of Verapamil,Lidocaine,and VerapamilLidocaine combination,Anesth Analg 85 1005 -10
NhoJS,LeeSY,KangJM,KimMC,ChoiYK,ShinOY, 2009.Effects of maintaining a remifentanil infusion on the recovery profiles during emergence from anaesthesia and tracheal extubation,Br J Anaesth 10 817 -21
MuzziDA,BlackS,LosassoTJ,CucchiaraRF, 1990.Labetalol and esmolol in control of hypertension after intracranial surgery,Anesth Analg 70 68 -71
DysonA,IsaacPA,PennantJH,GieseckeAH,LiptonJM, 1990.Esmolol attenuates cardiovascular responses to extubation,Anesth Analg 71 675 -8
DuttaS,RudraA,RayM,SarkarA,MitraD., 1999.Haemodynamic changes during intubation and extubation in patients with mitral stenosis:Effects of Nitroglycerine and Esmolol,Ind J Anaesth 43 45 -53
RamsayMA,HuddlestonP,HammanB,TaiS,MatterG., 2004.The patient state index correlates well with the Ramsay sedation score in ICU patients,Anesthesiology 101 A338 -
TuranG,OzgultekinA,TuranC,DincerE,YukselG, 2008.Advantageous effects of dexmedetomidine on haemodynamic and recovery responses during extubation for intracranial surgery,Eur J Anaesthesiol 10 816 -20
KayhanZ,AldemirD,MutluH,OğüşE, 2005.Which is responsible for the haemodynamic response due to laryngoscopy and endotracheal intubation? Catecholamines, vasopressin or angiotensin?,Eur J Anaesthesiol 22 780 -5
GorczynskiRJ,ShafferJE,LeeRJ, 1983.Pharmacology of ASL-8052, a novel betaadrenergic receptor antagonist with an ultra short duration of action,Journal of cardiovascular pharmacology 5 668 -77
LowrieA,JohnstonPL,FellD,RobinsonSL, 1992.Cardiovascular and plasma catecholamine responses at tracheal extubation,Br J Anaesth 68 261 -263
UnalY,OzsoylarO,SariguneyD,ArslanM,YardimRS, 2008.The efficacy of esmolol to blunt the haemodynamic response to endotracheal extubation in lumbar disc surgery,Res J Med Sci 2 99 -104
SinghalSK,MalhotraN,KaurK,DhaiyaD, 2010.Efficacy of esmolol administration at different time intervals in attenuating hemodynamic response to tracheal intubation,Indian J Med Sci 64 468 -75
KarmarkarS,VarshneyS., 2008.Tracheal extubation,Contin Educ Anaesth Crit Care Pain 8 214 -220
Pérez PeñaJM,Olmedilla ArnalL,Jimeno FernándezC, 1991.Effect of an intravenous nitroglycerine bolus on the hemodynamic impact of laryngoscopy and intubation,Rev Esp Anestesiol Reanim 38 234 -7