No Detail Found!

Geotechnical Site Evaluation of Collapsed Margalla Tower in Islamabad Due to October 2005 Muzzafarabad Earthquake.

Author(s)
S Shoukat Civil Engineering Department, University of Hail, Saudi Arabia
ZU Rehman Civil Engineering Department, University of Hail, Saudi Arabia
K Mahmood Civil Engineering Department, University of Hail, Saudi Arabia
M Ashraf Civil Engineering Department, University of Hail, Saudi Arabia
Abstract
This study evaluates the bearing capacity and settlement of collapsed Margalla Tower due to 2005 Muzzafarabad Earthquake. The geotechnical investigation was conducted at the site to investigate sub-surface profile and to and to evaluate bearing capacity and settlement analysis by field as well as laboratory tests. The soil sampling (disturbed and undisturbed samples) was done by 21 m borehole at the site. The grain size distribution and the electric resistivity test results showed that the soil beneath the tower was mainly clayey and silty soil. The shear wave velocity based on standard penetration test SPT-N value results showed a range of 175 to 350 m/s. SD soil class was determined as per BCP 2007. The bearing capacity calculated by using laboratory as well as field test results showed a value of 253 kPa and 389 kPa at the raft foundation level. Similarly the settlement evaluation from laboratory as well as in-situ test showed 3.80 and 50 mm respectively and was within permissible limits. The geotechnical investigation reveals that the Margalla Tower was safe against bearing capacity and settlement.
Publication Details
Page(s) 117-122
DOI DOI not available
Published Journal: Technical Journal, Volume: 20, Issue: 3, Year: 2015

Request the full text from PASTIC

Keywords
Geotechnical Investigation, Margalla Tower, Bearing Capacity, Settlement
References
CapitalDevelopment Authority,,1992,,,,-
Flats,,,,,10,-
,1992,,private Ltd,,-
Report of Margalla Tower,,,,,10,-
,2006,,Geological Survey of Pakistan (GSP),,-
B. M. Das,,2007,,Published by Thomson Limited, Canada. Chapter 6,,147-154
M. Das,,2007,,Published by Thomson Limited, Canada. Chapter 4,83,259-283
,,Standard Test Methods for Laboratoryoratory Determination of Water (Moisture) Content of Soil,,2216,-
,,Standard Test Methods for Liquid Limit, Plastic Limit,,4318,-
,,Standard Test Method for Classification of Soils for Engineering Purposes” Unified Soil Classification System (USCS),,2487,-
,,[ix] ASTM D 3282. “Standard Practice for Classification of Soils and Soil-Aggregate Mixtures for Highway Construction Purposes” American Association of State Highway and Transportation Officials (AASHTO),,,-
,,Standard Test Method for Direct Shear Test of Soil Under Consolidated Drained Conditions”,,3080,-
,,Standard Test Methods One Dimensional Consolidation Properties of Soils Using Incremental Loading”,,2435,-
,1996,Foundation Analysis and Design” published by Mc Graw- Hill Companies,,,167-179
R. D.Holtz,W. D.Kovacs,,1981,An Introduction to Geotechnical Engineering”,,,284-296
B. C.Punmia,,1994,Soil Mechanics and Foundations” LAXMI Publications,,,737-738
,2007,Seismic Provision for Building Code of Pakistan” Ministry of Housing and Works Government of Pakistan Islamabad”,[xv] Building Code of Pakistan (BCP),,-