Abstract
Objective: To determine hemodynamic changes by using 0.75% and 0.50% hyperbaric bupivacaine for spinal anesthesia in caesarean section. Methodology: In this randomized clinical trial 200 patients of elective cesarean section with primigravida having age 20-40 years were included. Group I patients received 0.5% hyperbaric bupivacaine for spinal anesthesia and Group II patients received 0.75% hyperbaric bupivacaine for induction. In all patients, a total of 10.5 mg dose of hyperbaric bupivacaine was given. Patient's systolic blood pressure (SBP) and heart rate were noted before spinal anesthesia, immediately after anesthesia, after 5 minutes and 10 minutes of anesthesia. Necessity of rescue ephedrine and incidence of nausea/vomiting was noted in all patients. Results: After 5 minutes of spinal anesthesia, SBP significantly dropped in patients who received 0.75% hyperbaric bupivacaine as compared to patients who received 0.5% bupivacaine 107.95 ±13.49 mmHg vs. 112.76±11.49 mmHg, respectively with p value 0.007. After 10 minutes of anesthesia there was no difference in SBP in both groups. There was significant difference in heart rate after 10 minutes of anesthesia and decrease in heart rate was more in group II (p value 0.006). Nausea/vomiting occurred in 23% patients in group II and in only 1% patients in group I. Rescue ephedrine was given in 21% patients in group I and 35% patients in group II. Level of block was T6 in 25% patients in group I and 47% patients in group II (p value 0.001). Conclusion: 0.5% hyperbaric bupivacaine was associated with better hemodynamic stability and reduced risk of bradycardia, necessity of rescue ephedrine and nausea/vomiting.
Publication Details
Page(s) 87-90
DOI DOI not available
Published Journal: Journal of Postgraduate Medical Institute, Volume: 32, Issue: 1, Year: 2018

Request the full text from PASTIC

References
Karim M, Banik D, Hye A, Huda Q, Laskar M, Banik D et al. Effect of site of injection on spread of spinal anaesthesia with hyperbaric bupivacaine. J Bangla Soc Anaesthesiol 2009; 20:51-5.
JabalameliM,HazeghN,GholamiS.,,2012,The effects of hyperbaric or isobaric bupivacaine on bispectral index in spinal anesthesia for cesarean section,J Res Med Sci,17,176-81
GuptaR,BograJ,SinghPK,SaxenaS,ChandraG,KushwahaJK,,2013,Comparative study of intrathecal hyperbaric versus isobaric ropivacaine: A randomized control trial,Saudi J Anaesth,7,249-53
MercierFJ,BonnetMP,De la DorieA,MoufoukiM,BanuF,HanafA,,2006,Spinal anaesthesia for caesarean section: fluid loading, vasopressors and hypotension,Ann Fr d'anesth Reanim,26,688-93
KøhlerF,SørensenJF,Helbo-HansenHS,,2002,Effect of delayed supine positioning after induction of spinal anaesthesia for caesarean section,Acta Anaesthesiol Scand,46,441-6
ScullTJ,CarliF,,1996,Cardiac arrest after Caesarean section under subarachnoid block,Br J Anaesth,77,274-6
LøvstadRZ,GranhusG,HetlandS. Bradycardia,,2000,and asystolic cardiac arrest during spinal anaesthesia: a report of five cases,Acta Anaesthesiol Scand,44,48-52
SikanderRI,,2009,Comparison of haemodynamic, block level and patient comfort by using 0.75% & 0.5% hyperbaric bupivacaine in caesarean section,Ann Pak Inst Med Sci,5,259-62
AmjadQUA,SharifA,KhanA,,2016,hyperbaric bupivacaine given intrathecally in elective lower segment caesarean section,Khyber Med Uni J,8,78-81
NorrisMC,,1988,Height weight and the spread of subarachnoid hyperbaric bupivacaine in the term parturient,Anesth Analg,67,555-8
EkeløfN,JensenE,PoulsenJ,ReinstrupP,,1997,Weight gain during pregnancy does not influence the spread of spinal analgesia in the term parturient,Acta anaesthesiol Scand,41,884-7
NorrisM,GutscheBB,CheekTG,,1990,Patient Variables and the Subarachnoid Spread of Hyperbaric Bupivacaine in the Term Patient,Obstet Anesth Digest,10,162-
ChungC,BaeS,ChaeK,ChinY.,,1996,Spinal anaesthesia with 0.25% hyperbaric bupivacaine for Caesarean section: effects of volume,Br J Anaesth,77,145-9
ChanVW,PengP,ChinyangaH,LazarouS,WeinbrenJ,,2000,Determining minimum effective anesthetic concentration of hyperbaric bupivacaine for spinal anesthesia,Anesth Analg,90,1135-40
RoofthooftE,,2008,Low-dose spinal anaesthesia for Caesarean section to prevent spinal-induced hypotension,Curr Opin Anesthesiol,21,259-62
GoyalA,ShankaranarayanP,GanapathiP.,,2015,A randomized clinical study comparing spinal anesthesia with isobaric levobupivacaine with fentanyl and hyperbaric bupivacaine with fentanyl in elective cesarean sections,Anesth Essays Res,9,57-62
ChariVRR,GoyalA,SengarP,WaniN.,,2013,Comparison between intrathecal isobaric ropivacaine 0.75% with hyperbaric bupivacaine 0.5%: A double blind randomized controlled study,Anaesth Pain Intens Care,17,261-6
DaviesP,FrenchG.,,2006,A randomised trial comparing 5 mL/ kg and 10 mL/kg of pentastarch as a volume preload before spinal anaesthesia for elective caesarean section,Int J Obstet Anesth,15,279-83
VermaR,MishraL,NathS.,,2005,Efficacy of polygeline preloading in prevention of hypotension following CSEA,Indian Soc Anaesth,49,105-8
SomboonviboonW,KyokongO,CharuluxanananS,NarasethakamolA,,2008,Incidence and risk factors of hypotension and bradycardia after spinal anesthesia for cesarean section,J Med Assoc Thai,91,181-7