No Detail Found!

Parametric study of NOx emissions in circulating fluidized bed combustor.

Author(s)
S. Khurram Institute of Chemical Engg. &Tech. University of the Punjab, Lahore, Pakistan
S. Mahmood Institute of Chemical Engg. &Tech. University of the Punjab, Lahore, Pakistan
Waqar A. Khan NFC Institute of Engineering and Fertilizer Research(IEFR), Faisalabad, Pakistan
A. Najaf NFC Institute of Engineering and Technological Training (IET), Multan, Pakistan
Niaz A. Akhtar National Textile University, Faisalabad, Pakistan
Abstract
Fluidized bed combustion behavior of coal and biomass is of practical interest due to its significant involvement in heating systems and power plant operations. This combustion behavior has been studied by many experimental techniques. Use of biomass in coal-fired power plants results in high efficiencies and fuel diversity. Co-combustion experiments were carried out in a pilot scale test facility of circulating fluidized bed combustor (70KW thermal). Effect of operating parameters on the NOx emissions is studied while burning coal with wheat straw. Relation between NOx emissions and operating parameters like bed temperature, excess air ratio, air staging, Ca/S molar ratio and fluidizing air velocity have been studied and discussed.
Publication Details
Page(s) 61-68
DOI DOI not available
Published Journal: Journal of Pakistan Institute of Chemical Engineers, Volume: 40, Issue: 1, Year: 2012