Comparison of three methods of dose optimization in brachytherapy of gynecological tumours-a local experience.

Author(s)
H. Zainab Gujranwala Institute of Nuclear Medicine and Radiotherapy (GINUM), Gujranwala, Pakistan
R. Hussain Nuclear Medicine Oncology & Radiotherapy Institute (NORI), Islamabad, Pakistan
S. Murad Gujranwala Institute of Nuclear Medicine and Radiotherapy (GINUM), Gujranwala, Pakistan
M. Riaz Gujranwala Institute of Nuclear Medicine and Radiotherapy (GINUM), Gujranwala, Pakistan
S. Khatoon Gujranwala Institute of Nuclear Medicine and Radiotherapy (GINUM), Gujranwala, Pakistan
Abstract
Radiotherapy is very common in many hospitals of the world. However, there is very little understanding of radiation dose distribution and calculations in intracavitary treatments of cancers in developing countries like Pakistan. The conventional manual dose calculation procedures sometimes do not give correct dose estimates and result in inappropriate dose delivery to the tumour which causes serious clinical complications. In this study we compared three methods of volumetric dose optimization to deliver dose to target area in intracavitary high dose rate brachytherapy (HDR) of cancer of the cervix. Recommendations of report of international commission on radiological units (ICRU-38) were followed in these methods. The main objective of the study was to assess the relative efficacy of the procedures of calculation in our environment. The three treatment planning procedures were: (i) Optimization by normalizing dose to 100% at conventional point ‘A’, (ii) Computer aided optimization, (iii) Manual optimization. Ten patients of carcinoma of cervix were selected who were first treated with external beam therapy (50Gy/25 fractions). In the last week of external beam therapy patients were planned for HDR brachytherapy (20 Gy; 5Gy/wk) to deliver total tumour dose of 70 Gy with Ir-192 source (Eavg=0.38 MeV, T1/2= 74 days). The recommended tumour dose is 75-90 Gy according to ICRU-38 but at NORI 70-74 Gy is prescribed depending upon the size and stage of tumour. The ICRU-38 reference points like B (for bladder, R for rectum) etc. were marked. Doses were calculated at all the reference points. 60 Gy reference volumes and volume enclosed by 20 Gy were calculated manually by applying formula, V=Height×Width×Thickness and by dose volume histogram methods for all the three dose optimization techniques. The calculations were performed on specific points following HWT formula, DVHs and computer programmes. One way analysis of variance (ANOVA) was used to test the variation in doses at different reference points. Chi square test was applied where two variables were compared. Dose estimates varied from 0.5 to 19.999 Gy at various points. Mean dose volume estimates for 60 Gy isodose curves varied from 195.4 to 775.8 cm3, whereas for 20 Gy isodose curves the estimates were between 60 and 307.8 cm3. The comparison of doses recorded by three optimization techniques shows that only doses at point ‘A’ and point ‘B’ differ significantly (p0.05). The study shows that optimization by normalizing dose at point ‘A’ results in higher bladder and rectum doses (94% and 79% of point A dose) beyond their tolerable limits (75% and 70% of point A dose) as compared to computer aided optimization (73 and 61% of the prescribed dose at point ‘A’) and manual optimization (57 and 53 % of the prescribed dose at point ‘A’). Student t test shows significant variation (p
Publication Details
Page(s) 309-317
DOI DOI not available
Published Journal: Nucleus, Volume: 49, Issue: 4, Year: 2012