No Detail Found!

Gas chromatography-flame ionization determination of Benzaldehyde in non-steroidal anti-inflammatory drug injectable formulations using new ultrasound-assisted dispersive liquid-liquid microextraction.

Author(s)
Hossein Ali Mashayekhi Department of Chemistry, Tonekabon Branch, Islamic Azad University, Tonekabon, Iran
Khalil Pourshamsian Department of Chemistry, Tonekabon Branch, Islamic Azad University, Tonekabon, Iran
Mohammad Rezaee Nuclear Fuel Cycle Research School, Nuclear Science and Technology Research Institute, Atomic Energy Organization of Iran, P.O. Box 14395-836, Tehran, Iran
Seyed Javad Ahmadi Nuclear Fuel Cycle Research School, Nuclear Science and Technology Research Institute, Atomic Energy Organization of Iran, P.O. Box 14395-836, Tehran, Iran
Shirin Sadeghi Garmaroudi Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
Abstract
In this study, simple and efficient ultrasound-assisted dispersive liquid-liquid microextraction combined with gas chromatography (GC) was developed for the preconcentration and determination of benzaldehyde in injectable formulations of the non-steroidal anti-inflammatory drugs, diclofenac, Vitamin B-complex and Voltaren injection solutions. Fourteen microliters of toluene was injected slowly into 10 mL home-designed centrifuge glass vial containing an aqueous sample without salt addition that was located inside the ultrasonic water bath. The formed emulsion was centrifuged and 2 µL of separated toluene was injected into a gas chromatographic system equipped with a flame ionization detector (GC-FID) for analysis. Several factors influencing the extraction efficiency as the nature and volume of organic solvent, extraction temperature, ionic strength and centrifugation time were investigated and optimized. Using optimum extraction conditions a detection limit of 0.3 µg L-1 and a good linearity in a calibration range of 2.0-1000 kg L-1 were achieved for analyte. This proposed method was successfully applied to the analysis of benzaldehyde in three injection formulations and relative standard deviation (RSD) of analysis (n=3), before spiking with standard benzaldehyde were 3.3, 2.0 and 1.3% for Na-diclofenac, vitamin B- complex and voltaren, respectively and after spiking of standard benzaldehyde (0.3 mg L-1), the RSD were 6.5, 3.6 and 2.8% for Na-diclofenac, vitamin B-complex and voltaren, respectively.
Publication Details
Page(s) 1253-1259
DOI DOI not available
Published Journal: Journal of Chemical Society of Pakistan, Volume: 34, Issue: 5, Year: 2012

Request the full text from PASTIC

0

Citations

0

Downloads

64

Views