E. Coli and total coliform have always been used as indicators of great threat to human health. The present study was conducted for the microbial analysis of water samples collected from different water filter units installed in different departments of Lahore College For Women University (LCWU), Lahore, alongwith some physical parameters like Temperature, pH, Total Dissolved Solids (TDS) and Electrical conductivity. Microbial load (E.Coli and Total Coliform) was determined using culture media i.e Eosin Methylene Blue Agar (EMB). The spread plate method was employed for the isolation of microorganisms. The bacterial species were identified on the basis of their morphology. The value of pH was within permissible limits. The value of temperature ranged from 22-25°C. The TDS values ranged from 800-1300mg/I. In most cases the TDS values were higher than the WHO permissible limit. The values of electrical conductivity was higher than the permissible limit in mostly departments. The Total coliform and E.Coli contamination was also high in most of the drinking water samples from the filter units. Possible recommendations are also provided for the water from filter units. So that the filter units must be installed and maintained properly for pure and safe drinking water use.