No Detail Found!

Modeling of shear socketed piers in rocks part-I: experimental load tests.

Author(s)
Aziz R. Khan Mining Engineering Department, NWFP University of Engineering Technology, Peshawar, Pakistan
Abstract
The behaviour of shear socketed piers is controlled by several factors such as the rock mass modulus, the stiffness of the piers, the roughness of the pier-rock interface, the geometry of the rock socket and the quality of the socket walls. There is no single design method available, to date, that incorporates all these basic factors. A combined laboratory and analytical study was initiated to address key issues of socketed piers. This paper, which is the first of a three part series, examines some of the fundamental factors that affect the side resistance of shear socketed piers under static axial loading. Laboratory load tests were carried out on model piers socketed into hydrostone. The main purpose of these tests was to investigate the effect of the relative stiffness of the piers and surrounding rock material and the roughness of the pier-rock interface on the shaft resistance of piers socketed in soft rocks. The piers were 254 mm (10 in.) in length and 70 mm (2.75 in.) in diameter. Hydrostone was used to simulate rocks of very low to medium strength and plane concrete was used to construct the piers. Comparison between the results of the laboratory push tests and existing empirical predictions of shaft resistance of socketed piers is presented.
Publication Details
Page(s) 51-57
DOI DOI not available
Published Journal: Journal of Engineering and Applied Sciences, Volume: 17, Issue: 2, Year: 1998

Request the full text from PASTIC

0

Citations

0

Downloads

91

Views