The subsurface pipe drains are installed to combat the problem of waterlogging. The PVC sub-surface drain pipes are wrapped in the gravel filter/envelope for enhancing hydraulic performance of the drain pipes as well as to protect against the siltation of the drain pipes. A filter is deemed to have failed if it does not perform its intended purposes effectively. The filter/envelope design is usually based on an average gradation curve of the base material. However, a considerable variability of the size of the base material is usually observed. Therefore, the filter/envelop will not perform adequately at some places in the project area. A study was conducted to determine the impact of the spatial variability of the projects base material on the performance of the gravel envelope for the sub-surface drains. It was found that the spatial variability has significant effect on the performance of the gravel filter/envelope and an average probability of failure of 30% was found for the conditions of Fourth Drainage Project, Faisalabad (Pakistan). Therefore the project area should be divided into more homogeneous sub-areas and filter/envelope be designed for each sub-area separately to reduce the risk of filter/envelope failure.