No Detail Found!

Spectrophotometric flow injection determination of nitrate and nitrite in potable water using 8-Hydroxyquinoline.

Author(s)
M. Yaqoob Institute of BioChemistry, University of Baluchistan, Quetta, Pakistan
M. A. Siddiqui Institute of BioChemistry, University of Baluchistan, Quetta, Pakistan
M. Masoom Institute of BioChemistry, University of Baluchistan, Quetta, Pakistan
Abstract
A method based on the principle of flow injection analysis is described for the determination of nitrate and nitrite. A minicolumn of copperized cadmium is used which reduces nitrate to nitrite, which in turn is diazotized with 4-aminobenzoic acid and 8-hydroxyquinoline. The resulting azo compound is quantified at 485 nm. The procedure is applied to potable water samples. The sampling rate for both species was 60 hr-1 The relative standard deviation was 0. 8% for nitrite and 1. 0% for nitrate.
Publication Details
Page(s) 248-252
DOI DOI not available
Published Journal: Journal of Chemical Society of Pakistan, Volume: 13, Issue: 4, Year: 1991

Request the full text from PASTIC

0

Citations

0

Downloads

59

Views