No Detail Found!

Increasing accuracy of frequency measurement in a microprocessor based multi measuring system.

Author(s)
Zubair Ahmad Khan Electrical Engineering Department, University of Engineering & Technology, Lahore, Pakistan
Abstract
Frequency measurement in the field of electrical engineering is very important and hence various techniques have been used to measure it. A technique which increases the accuracy of the frequency measurement in a multi-measuring system (1), is described. This technique has been developed to get better accuracy around a central frequency such as 50 ± 5%Hz etc., Which will reduce the range of measurement but autoranging (2) can be used to extend it. It is possible to achieve high accuracy in the measurement of even when an 8-bit A/D conversion is employed.
Publication Details
Page(s) 4-8
DOI DOI not available
Published Journal: New Horizons: Journal of the Institution of Electrical & Electronics Engineers Pakistan, Volume: 23, Issue: , Year: 1993

Request the full text from PASTIC

0

Citations

0

Downloads

15

Views