Phenol is one of the most common pollutant of the environment. It enters in the soil and water through different path ways like cooking, plastic manufacturing, oil purification timer and pharmaceutical industries. In the present work effluent samples were taken from a pharmaceutical industry. Analysis of the effluent was made by using HPLC. The result indicates high concentration of para amino phenol, para nitroso phenol, phenol and ortho nitroso phenol. These phenols were isolated by using various techniques like solvent extraction, leaching, and column chromatography etc. Column chromatographic separation of the phenol was found the most efficient technique and is reported here in detail. The results indicate that these techniques are reported here in detail. The results indicate that these techniques may be used for the economical extraction of phenols of high purity.