No Detail Found!

Improvement in the assay of lead in commercial tin using dithizone as a chromogenic reagent and its comparison with atomic absorption spectroscopic method.

Author(s)
S. Bial Butt Nuclear Chemistry Division, Pakistan Institute Nuclear Science & Technology, Islamabad, Pakistan
M. Riaz Nuclear Chemistry Division, Pakistan Institute Nuclear Science & Technology, Islamabad, Pakistan
Ehsan-Ul-Haq Nuclear Chemistry Division, Pakistan Institute Nuclear Science & Technology, Islamabad, Pakistan
Abstract
Acute and chronic effects of lead on human health are well documented. Tin is being used extensively for the protective coating/plating of cans, which are used in food preserving industry. Tin of different purity is available in the market and it is suspected that lead may be one of the major impurities which might contaminate the packed food on its long storage. Spectrophotometric method using dithizone as a chromogenic reagent in combination with an improved sampling procedure has been used for the determination of lead at 520 nm. Lead level in most of the commercial tin samples was in the range of 300-600 µg/g. Lead levels of the analyzed samples, determined by spectrophotometric method, are in close agreement with the results obtained using atomic absorption spectrometry.
Publication Details
Page(s) 101-103
DOI DOI not available
Published Journal: Nucleus, Volume: 33, Issue: 1--2, Year: 1996

Request the full text from PASTIC

0

Citations

0

Downloads

84

Views