No Detail Found!

Effect of length and diameter of wire on the interfacial shear stresses in wire embedded concrete specimens due to pull-out of wire.

Author(s)
I. A. Pathan Mehran University of Engineering & Technology, Jamshoro, Pakistan
Abstract
The pull-out loads were determined for the single wire embedded concrete specimens experimentally. The average shear strength, shear strength of the interface and frictional shear stresses were calculated for various diameters and lengths of embeded wire using Greszczuk's theory of interfacial stresses. Results indicate that frictional shear stresses at the interface remain constant with the increase in length of the embedded wire. The shear strength of the interface and frictional shear stresses are found to be increasing with the increase in the diameter of the wire.
Publication Details
Page(s) 1-6
DOI DOI not available
Published Journal: Mehran University Research Journal of Engineering and Technology, Volume: 1, Issue: 4, Year: 1982

Request the full text from PASTIC

0

Citations

0

Downloads

49

Views