Experimental determination of parameters of a double-cage equivalent circuit and prediction of the separate steady-state inner and outer-cage rotor torques is discussed for the first time. In future this could help in the verification of design parameters & understanding and improvement of the motor. The author also discusses the effect of variation of stator leakage reactance and mutual reactance between the cages on rotor side parameters and over all performance of the motor. The variation of curves for individual cage torques similar to their total torques which is itself very close to the torques claimed by the manufacturers on their design sheet data.