Coal sample obtained from Makarwal coal fields was demineralized with HNO3 solutions and the trace elements were determined in the acid extracts using atomic absorption spectrophotometer. It was found that Ca and Fe were present in higher quantities, whereas Mn was present in the least amount in the acid extracts. The amounts of most of the trace elements in the HNO3 extracts were quite comparable to that in the HCI extracts, however they were quite high, compared to that in the H2O extracts. Time of equilibration and concentration of HNO3 have positive effect on the amounts and percent extractabilities of trace elements. However effect of time is not very significant as compared to concentration.