The e.m.fs. of the three thermocouples designed, Cu/Constantan (cu60, Ni40) Chromel (Ni90, Cr10)/Con-stantan (Cu60, Ni40) and Cu/Chromel (Ni90, Cr10) were noted after small intervals of temperatures between 77.3 (B.P. LN2) and 300°K with a self designed Cryos tat and Precision potentiometer. Thermoelectric power (sensitivity) of thermocouples was noted at 77.3 and 273 'K. The first two thermocouples showed comparatively greater sensitivities throughout the temperature range. Thermocouples were found reproducible and were calibrated against CLTS (Cryogenic Linear Temperature Sensor) thermometer. 539.1 Nuclear Atomic & Molecular Physics 539.17.012 Excitation Function Nuclear Reactions