Abstract
The dose rate distribution of the irradiation source (Issledovatel, USSR) was determined by the semiconductor detector current measurement and mono-chlorobenzene dosimeter methods with oscillotitrator readout instrument. In both the methods the maximum dose rate was observed at 100 mn height and 55 rrm diameter of the radiation chamber. Dose rate distribution by Fricke modified Fricke dosimetry indicated that the maximum dose rate was 0.96 Mrad/hr at 100 rrm height from the centre of the irradiation chamber base. The transit dose was also worked out which was 4.8 krod.
Publication Details
Page(s) 45-52
DOI DOI not available
Published Journal: Physical chemistry, Volume: 4, Issue: 1, Year: 1985