No Detail Found!

Controlled-current coulometric titration of phenol and p-amino phenol with electrolytically generated bromine using a platinum generating anode.

Author(s)
M. M. Qureshi Institute of Chemical Engineering & Technology, Punjab University, Lahore, Pakistan
Jaroslav Zyka Analytical Chemistry Department, Charles University, Prague, Czechoslovakia
Abstract
Bromination of phenol and p-amino phenol was studied by electrogenerated bromine in presence of glacial acetic acid as the medium. Phenol gave monobromo derivatives upto 50°C and diderivatives at 80°C.In case of p-amino phenol two and six electron change was observed by properly adjusting the percentage of acetic acid and temperature during these determinations.
Publication Details
Page(s) 33-36
DOI DOI not available
Published Journal: Pakistan journal of scientific research, Volume: 33, Issue: 1--4, Year: 1981