No Detail Found!

Wall heat transfer coefficients of Dowtherm - ❑ in-fixed beds.

Author(s)
M. M. Ahmad Chemical Engineering Department, University of Engineering & Technology, Lahore, Pakistan
J. R. Khan Chemical Engineering Department, University of Engineering & Technology, Lahore, Pakistan
G. M. Mamoor Chemical Engineering Department, University of Engineering & Technology, Lahore, Pakistan
Abstract
An experimental investigation into the effect of packing diameter, fluid velocity and thermal conductivity upon the wall heat transfer coefficients of Dowtherm-A, flowing in closed loop through a packed-bed reactor heated radially at the wall, has been made. Spherical and cylindrical shaped particles are employed as the packing material. A theoretical equation is developed which could predict the wall heat transfer coefficients of Dowtherm. The values of heat transfer coefficients so obtained are compared with the experimental data; an agreement is found within an accuracy of ±9%.
Publication Details
Page(s) 227-230
DOI DOI not available
Published Journal: Pakistan Journal of Scientific and Industrial Research, Volume: 29, Issue: 3, Year: 1986

Request the full text from PASTIC

0

Citations

0

Downloads

119

Views