Liquid-liquid extraction of oxalic, malonic and succinic acids from their aqueous solutions has been studied at 25°C, 35°C. 55°C, and 65° C with amyl alcohol, amly acetate and aniline as solvents. Extraction with ether is also reported but at lower temperatures, i.e. at 15°C, 20°C and 25°C. As the molecular weight of the solute increases, the distribution coefficient decreases and the per cent extraction increases. The rising temperature favours the aqueous layer and correspondinglv the per cent extraction decreases. The decreasing effectiveness of the various extractants is in the following order:-amyl alcohol aniline amyl acetate ether