Tabikh and Clemena`s selective solution mortar analysis for determining mix-ratio involves several time-consuming steps. In this paper an attempt has been made to modify and further simplify it by eliminating many chemical and weighing operations, with the use of a volume measuring tube. Methanol has been substituted by methylated spirit to fairly reduce the cost factor. Appreciably reliable results are obtained with this method provided the suggested precautionary measures are properly applied. The method is quite simple to be adopted easily, by an average worker without any difficulty, for rapid determination of cement content in mortar and concrete.