No Detail Found!

Study of the oxidation of platinum (II) with Hexaminecobalt (III) tricarbonatocobaltate (III).

Author(s)
M Hanif
Manhood Ahmad
M. Sarwar Chaudhry
Abstract
Platinum (II) is directly oxidized to platinum (IV) and consequently cobalt (III) is reduced to cobalt (II). The volume consumption of the titrant is a direct proof of the fact. The reaction proceeds very fast and one titration could be done in about 2-3 min. The end point, i.e. change from red to pale blue, Is very sharp and persists for about 3 min; therefore, it is detected without any difficulty. The effect of diverse ions on this determination has been studied. Palladium up to about 4.7 fold in excess to platinum does not interfere in any way with palladium determination while irridium, osmium and gold interfere strongly. The interference of gold can be eliminated by adding a known excess of ethyl acetate to a solution of platinum test solution containing gold. The solution is shaken well after which the ethyl acetate layer is separated with a separating funnel. This is repeated with fresh ethyl acetate and the resulting aqueous solution is titrated against the titrant in the usual manner. The method reported here is quite simple, precise and accurate.
Publication Details
Page(s) 321-322
DOI DOI not available
Published Journal: Pakistan Journal of Scientific and Industrial Research, Volume: 20, Issue: 4--5, Year: 1977

Request the full text from PASTIC

0

Citations

0

Downloads

77

Views