No Detail Found!

Determination of peroxydisulphate by hydrazine sulphate : modified procedures.

Author(s)
M Azeem
A. A. M. Wali
Abstract
The accuracy of the two procedures, for the determination of K2S2O8, is comparable with the ferrous sulphate method. The experimental error in the assayed values of K2S2O8`, is with-in the permissible limit of + 0.5%. The results were independent of the concentration of either K2S2O8 or N2H4H2SO4 or both, and were not affected by the addition of excess of NaHCO3. Determination of S2O8 -- by given methods involves intermediate steps and these methods are time consuming because the reagents used in these methods cannot be stored for long. Moreover, the reagents need to be standardized frequently while in the procedure under discussion, the titrant, hydrazine sulphate can be stored for longer periods without appreciable deterioration.
Publication Details
Page(s) 211-219
DOI DOI not available
Published Journal: Pakistan Journal of Scientific and Industrial Research, Volume: 20, Issue: 3, Year: 1977