Mg and Ca are visible under UV light when sprayed with 8-hydroxygquinoline. For Sr and Ba, the chromatoplate is sprayed with sodium rhodizonate followed by exposure to NH, vapours. The best results were Obtained with 6M HC1-methanol (1:5). A fine separation of Mg and Ca has also been made on cellulose powder impregnated with tributyl phosphate in CC1, using $M HC1 as eluent. Mg and Ca rings are only visible under UV light when exposed to NH3-vapours. By this proceudre presence of Mg, Ca, Sr and Ea has been confirmed in some ore samples. Rf values may vary slightly, but the sequence of separation is the same. A solvent extraction scheme is applied when other interfering cations are present. Lithium, though extracted with alkaline earth metals, gives dim coloured ring with 8-hydroxyquinoline, but has different Rf values. Similarly Th and Ce form dim coloured rings with sodium rhodizonate having different Rf values; hence do not interfere with the identification of alkaline earth metals.