A study was conducted to develop an efficient drier in the form of a dish type solar air heater that could dry grapes. A small solar air heater, connected to a drying chamber was developed at Khyber Agency (FATA), Pakistan in the month of August, 2011 for drying grapes. Efficiency of this solar air heater was evaluated in the Department of Agricultural Mechanization, Faculty of Crop Production Sciences, Khyber Pakhtunkhwa Agricultural University, Peshawar, Pakistan. Two air flow rates i.e. 1 natural (0.01kg/sec) and 2 convective (0.21 kg/sec and 0.28 kg/sec) air flow rates at different day timings. The results showed that flow rates significantly (P < 0.001) affected efficiency of solar air heater. Efficiency increased from 12 percent at natural to 24 percent and 35 percent at convective air flow rates of 0.21 and 0.28 kg per second, respectively. Further, grapes were dried at temperature of 50°C and less than 20 percent humidity. Air flow rate of 0.28 kg per second was given for drying in drying chamber and grapes were dried less than a moisture content of 10 percent. It was observed that grapes were dried in 24 hours by dish type solar air heater’s drying chamber. The study concluded that dish type solar air heater for drying grapes should be operated at high flow rates to achieve high efficiency at minimum time. Solar air heater also maintained the quality of grapes and minimized losses from pest attacks.