No Detail Found!

Comparative performance of gas turbine engine fitted with a recuperator and a regenerator.

Author(s)
Abdul Aziz Leeds University, England, UK
M. Ibrahim University of Karachi, Karachi, West-Pakistan
Abstract
Presents the details of a theoretical investigation into the economy in fuel consumption and the gain in efficiency possible with a recuperator and a regenerator when used with a typical stationary gas turbine engine. Heat exchangers when fitted to a gas turbine engine, improve the engine efficiency and lower its fuel consumption. It is observed that of the two main types of heat exchangers, the regenerator is more effective than the recuperator. With a regenerator the specific fuel consumption is lowered by about 4.5% and overall efficiency is improved by about 5% as compared to a recuperator cycle, both heat exchangers having the same thermal ratio of 0.6.
Publication Details
Page(s) 99-109
DOI DOI not available
Published Journal: Science & Industry, Volume: 3, Issue: 2, Year: 1965

Request the full text from PASTIC

0

Citations

0

Downloads

43

Views