No Detail Found!

Comparison of low dose spinal anesthesia with general anesthesia in pre-eclamptic parturients undergoing emergency cesarean section.

Author(s)
Atanas G. Sivevski Department of Anesthesiology, University Clinic of Gynecology and Obstetrics, University `Ss. Cyril & Methodius" Faculty of Medicine, Skopje, Republic of Macedonia
Marija V. Sholjakova Department for Doctoral studies University `Ss. Cyril & Methodius" Faculty of Medicine, Skopje, Republic of Macedonia
Andrijan B. Kartalov Research` Department at University Clinic of Anesthesiology, University `Ss. Cyril & Methodius" Medical Faculty, Skopje, Republic of Macedonia
Biljana K. Kuzmanovska Research` Department at University Clinic of Anesthesiology, University `Ss. Cyril & Methodius" Medical Faculty, Skopje, Republic of Macedonia
Vesna M. Durnev Research` Department at University Clinic of Anesthesiology, University `Ss. Cyril & Methodius" Medical Faculty, Skopje, Republic of Macedonia
Abstract
Objectives: Both spinal (SA) and general anesthesia (GA) are commonly used for operative management of pre-eclampsia parturients. Low dose SA is practical with faster onset and with fewer complications. This study aims to compare the effect of low dose SA or GA on neonatal wellbeing for preeclamptic par-turients undergoing emergency cesarean section Methodology: This prospective randomized study was carried out at University Clinic of Anesthesiology and University Clinic of Gynecology and Obstetrics at UCIM, Skopje, Republic of Macedonia. Sixty (n=60) pre-eclamptic parturients undergoing emergency cesarean section were divided in two groups receiving low dose spinal (SA) or general anesthesia (GA). Intra operatively we monitored and evaluated parturi-ents` ECG, heart rate, noninvasive blood pressure, ephedrine requirement`s, as well as neonatal umbilical artery ( UA) blood gas samples and Apgar scores. Main outcome measure was a comparison of the influence of two different anesthesia methods (low dose SA vs. GA) on neonatal wellbeing, measured by umbilical artery (UA) blood gases, Apgar score and mark-ers of fetal hypoxemia with non-invasive hemodynamic status in 60 pre-eclampsia parturients undergoing non-elective (emergency) cesarean section (CS). Results: There was no statistical difference in the mean arterial blood pressure between the groups (90.6 ± 12.9 vs. 96 ± 8.9 mm Hg), as well as in the neonatal acid-base status and BE (p> 0.05). Spinal anes-thesia patients required more ephedrine (8,5 vs. 1.7 mg, p 7 in 96% of newborns delivered after spinal anesthesia, while 75% after general anesthesia (p
Publication Details
Page(s) 37-43
DOI DOI not available
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 19, Issue: 1, Year: 2015

Request the full text from PASTIC

0

Citations

0

Downloads

52

Views