No Detail Found!

Efficacy of motion correction in absolute quantification of colonic PETCT for drug response therapy.

Author(s)
Michael A Masoomi Department of Nuclear Medicine, Farwaniya Hospital, Kuwait
Andy Robinson Department of Nuclear Medicine, Farwaniya Hospital, Kuwait, Nuclear Medicine Physics, Queen Alexandra Hospital, UK
Yassine Bouchareb Barts Health NHS Trust, London
Seyedali Hejazi Harvard Medical School, Boston, USA
Nicholas M Spyrou Barts Health NHS Trust, London, University of Surrey, Guildford, UK
Abstract
Aims The study aimed at: a) characterizing and correcting bowelmotion induced artefacts whilst imaging the region in preand postdrug therapy 18FFDG scans; b)developing a motion model of the gut using a fully 3D nonrigid registration technique for applying to NACT digitised images. Methods A motion correction technique for PETCT scans, particularly those of the abdomen and colon was developed. Attenuation and activity image volumes were generated at different points in the respiratory cycle using the Nonuniform Rational Bspline Cardiac Torso (NCAT) anthropomorphic phantom. The movement of the abdomen was characterised as part of the image registration process and assessment of the motion correction technique was performed quantitatively with Region of Interest (ROI), image fidelity, and image correlation techniques; semiquantitatively with line profile analysis; and qualitatively by overlaying nonmotioncorrected and motioncorrected image frames. Results Motion correction was successful for frames that were substantially different to the reference (large motion); these frames had considerable differences between the ROI activities in the nonmotion corrected and reference frames. Large motion correction resulted in an improvement in image fidelity factor (from 0.848 to 0.976). Conclusion In principle, PETCT motion correction of the colon can be performed using image registration between different frames in the respiratory cycle. Clinically, frames at different points in the respiratory cycle can be obtained by respiratory gating during PET image acquisition. Future work can concentrate on developing this technique so that it can be applied to clinical data.
Publication Details
Page(s) 22-28
DOI DOI not available
Published Journal: Pakistan Journal of Nuclear Medicine, Volume: 3, Issue: 1, Year: 2013

Request the full text from PASTIC

0

Citations

0

Downloads

74

Views