No Detail Found!

Biosafety practices in different clinical laboratories in Karachi, Pakistan.

Author(s)
Saeed Khan Molecular Pathology, Dow Diagnostic Reference and Research Laboratory, Dow International Medical College, Dow University of Health Sciences Karachi, Pakistan
Fatin Zehra Molecular Pathology, Dow Diagnostic Reference and Research Laboratory, Dow International Medical College, Dow University of Health Sciences Karachi, Pakistan
Noorulaine Maqsood Molecular Pathology, Dow Diagnostic Reference and Research Laboratory, Dow International Medical College, Dow University of Health Sciences Karachi, Pakistan
Maria Zahid Molecular Pathology, Dow Diagnostic Reference and Research Laboratory, Dow International Medical College, Dow University of Health Sciences Karachi, Pakistan
Bilal Ahmed Molecular Pathology, Dow Diagnostic Reference and Research Laboratory, Dow International Medical College, Dow University of Health Sciences Karachi, Pakistan
Abstract
Introduction: In Pakistan the number of diagnostic and research laboratories is increasing in both public and private sectors but there is still a lack of awareness regarding biosafety practices among the lab employees. These employees can be technicians, technologists, researchers or even keeping staff who gets exposed directly or indirectly to a plethora of pathogens daily. The need is to spread awareness regarding the importance of fundamental biosafety practices. Objective:To determine and compare the level of awareness and implementation regarding biosafety practices among different laboratories and their workers in Karachi, Pakistan. Methodology: A survey was conducted from 10 different diagnostic laboratories of Karachi, participants were interviewed and made to fill out a questionnare. Result: In the category of general safety 60% confirmed that they receive a formal biosafety training. 20% of the participants received a safety handbook. Usage of personal protective equipments were 80%.however 10% labs provide eye station and emergency shower facilitiy and 60% of the participants confirmed that fire station was not available in their lab. In the category of equipments, 80% of the participants agreed that their equipments were in working order, 60%of the participants confirmed that the PPM of their equipments were carried out on regular basis and Back up cold storage was available in only 20% of the laboratories. 40% of the participants said that the maintenance of biosafety cabinets was carried out regularly in their laboratories and only 40% were unaware regarding the certification of their biosafety cabinets. Whereas Proper disinfection and decontamination of biosafety cabinets was carried out in 70% of the cases. Conclusion: The outcome of our survey confirms a lack of practice and implementation of good biosafety practices in the clinical laboratories.
Publication Details
Page(s) 94-97
DOI DOI not available
Published Journal: Journal of Dow University of Health Sciences, Volume: 8, Issue: 3, Year: 2014

Request the full text from PASTIC

0

Citations

0

Downloads

95

Views