No Detail Found!

diode laser trans-scleral cycloablation as surgical treatment for primary open-angle glaucoma after maximum tolerated medical therapy.

Author(s)
Jawad Bin Yamin Butt Layton Benevolent Trust Hospital Free Eye Care and Cancer Hospital Lahore, Pakistan
Tariq Mehmood Qureshi Layton Benevolent Trust Hospital Free Eye Care and Cancer Hospital Lahore, Pakistan
Muhammad Tariq Khan Layton Benevolent Trust Hospital Free Eye Care and Cancer Hospital Lahore, Pakistan
Anwar-Ul-Haq Ahmad Layton Benevolent Trust Hospital Free Eye Care and Cancer Hospital Lahore, Pakistan
Abstract
Purpose: To establish the role of Diode Laser Trans-scleral Cycloablation (DLCA) as a primary treatment choice in Open Angle Glaucoma (POAG) after maximum endured medical therapy. Material and Methods: It is a quasi-experimental study which was conducted at Layton Rahmatullah Benevolent Trust Free Eye Care and Cancer Hospital, Lahore (LRBT). The duration of study was 1 year (29-03-2013 to 29-03-2014). Sixty patients meeting the inclusion criteria (Inclusion Criteria were Primary Open Angle Glaucoma and Maximum tolerated oral / topical medication) Were selected from the Glaucoma unit of LRBT for this study. Twenty five to 30 burns of Diode Laser were applied to 270 degrees avoiding 3 and 9 o clock positions, 1.5 mm posterior to the limbus. Laser was set at duration of 1.5 seconds and power between 1500 and 2000 mw. The power was attuned till a popping sound was heard and then reduced to just below that level. Patients were followed up for a period of one year. Results: Out of a total of 60 eyes with mean age 52.73 ± 7.40 years, 36 (60%) were male and 24 (40%) were female. The mean pre-operative IOP was ± 41.62 mm Hg (The pre-operative IOP ranged from 28 mm Hg to 60 mm Hg). The mean post-operative IOP was 18.97 mm Hg on day one, 16.75 mm Hg at 1 week, 15.68 mm Hg at 1 month, 15.00 mm Hg at 6 months and by the end of a year it was about 14.15 mm Hg (The post-operative IOP ranged from 6 mmHg to 52 mm Hg). There was a considerable drop of more than 50% of post-operative IOP in contrast to pre-operative IOP. Conclusion: Diode Laser Trans-scleral Cycloablation is a convenient, swift, well – endured modus operandi that provides a modest and variable lowering of intraocular pressure with few Complications.
Publication Details
Page(s) 90-94
DOI DOI not available
Published Journal: Pakistan Journal of Ophthalmology , Volume: 30, Issue: 2, Year: 2014

Request the full text from PASTIC

0

Citations

0

Downloads

53