No Detail Found!

Performance evaluation of a flat plate solar collector as a drier for chillies and tomatoes.

Author(s)
Muhammad Hanif Department of Agricultural Mechanization, Faculty of Crop Production Sciences, University of Agriculture, Peshawar, Pakistan
Mansoor Khan Khattak Department of Agricultural Mechanization, Faculty of Crop Production Sciences, University of Agriculture, Peshawar, Pakistan
Masood-Ur-Rahman Department of Agricultural Mechanization, Faculty of Crop Production Sciences, University of Agriculture, Peshawar, Pakistan
Maazullah Khan Nuclear Institutes for Food and Agriculture (NIFA), Peshawar, Pakistan
Muhammad Amin Department of Agricultural Mechanization, Faculty of Crop Production Sciences, University of Agriculture, Peshawar, Pakistan
Muhammad Ramzan Department of Agricultural Mechanization, Faculty of Crop Production Sciences, University of Agriculture, Peshawar, Pakistan
Abstract
The research study was conducted to test the performance of a flat plate solar thermal collector as a drier. A 1.7 m2 wooden box was developed, having a volume of 0.50 m3 , which acted as insulation box for the solar thermal collector. In this box a V-corrugated steel sheet was placed at the center as an absorber, a 5.00 mm thick glass was used to cover the absorber. The solar thermal collector was connected to the drying box, having a volume of 48.50 m 3 . Performance of the solar collector was evaluated at seven different convective air flow rates (2.8, 5.8, 8.5, 11.7, 14.2 and 17.5 kg.min-1 ) from November 2011 to January 2012. The results showed that an increase in air mass flow rate significantly (P ≤ 0.001) increased the performance of the solar collector. The decrease in performance was also observed with the change of months of year. Drying environment was observed inside the drying box connected with the solar collector. The results obtained showed that performance of the solar collector was directly affecting the drying conditions inside the drying box. The temperature of the drying box for all air flow rates remained in the range of 40-45oC and humidity of less than 10%. Samples of chillies and tomatoes were dried using drying chamber. Chillies took 23 while tomatoes took 19 hours to dehydrate completely. It was concluded that the solar thermal collector may be operated at high mass flow rates of air from 9:00 am to 4:00 pm to achieve maximum performance of the drier and optimum drying conditions for agricultural products to be dried in the drying box of the collector.
Publication Details
Page(s) 63-67
DOI DOI not available
Published Journal: Science, Technology and Development, Volume: 33, Issue: 2, Year: 2014

Request the full text from PASTIC

0

Citations

0

Downloads

48

Views