No Detail Found!

Transatrial access for left atrial pressure (LAP) monitoring line placement in Arterial switch operation (ASO) in neonates.

Author(s)
Mohammad Irfan Akhtar Department of Anaesthesia, Aga Khan University Hospital, Karachi, Pakistan
Mohammad Hamid Department of Anaesthesia, Aga Khan University Hospital, Karachi, Pakistan
Muneer Amanullah Department of Surgery, Aga Khan University Hospital, Karachi, Pakistan
Khalid Ahsan Department of Anaesthesia, Aga Khan University Hospital, Karachi, Pakistan
Abstract
Left Atrial pressure monitoring is a useful and accurate method to guide Left ventricle filling in the patients who undergo Arterial switch operation for transposition of great arteries. We have used a different technique in three TGA patients for LA pressure monitoring line placement. After cleaning and draping,right internal jugular vein (rt IJV) located through 22G venous cannula, guide wire was put in followed by sliding the 22Gx8cm vygon arterial catheter over the guide wire into the right atrium that was directed transatrially into LA by the operating surgeon during atrial septum repair. The catheter was secured by silk on the neck and dressed with transparent dressing and was kept for a period of 48-72hrs. LA pressure monitoring is helpful in anticipating LV dysfunction in ASO.
Publication Details
Page(s) 1430-1432
DOI DOI not available
Published Journal: Journal of Pakistan Medical Association, Volume: 63, Issue: 11, Year: 2013

Request the full text from PASTIC

0

Citations

0

Downloads

76

Views