No Detail Found!

Comparison of real time polymerase chain reaction with microscopy and antigen detection assay for the diagnosis of malaria.

Author(s)
Saleem Ahmed Khan Department of Haematology, Armed Forces Institute of Pathology, Rawalpindi, Pakistan
Suhaib Ahmed Department of Haematology, Armed Forces Institute of Pathology, Rawalpindi, Pakistan
Nuzhat Mushahid Department of Pathology, Armed Forces Institute of Transfusion, Rawalpindi, Pakistan
Masood Anwer Islamic International Medical College, Rawalpindi, Pakistan
Shahzad Saeed Department of Medicine, Military Hospital, Rawalpindi, Pakistan
Farooq Ahmed Khan Department of Haematology, Armed Forces Institute of Pathology, Rawalpindi, Pakistan
Ghassan Umair Shamshad Department of Haematology, Armed Forces Institute of Pathology, Rawalpindi, Pakistan
Zulqarnain Joyia Department of Haematology, Armed Forces Institute of Pathology, Rawalpindi, Pakistan
Abstract
OBJECTIVE: To determine the sensitivity of a real time polymerase chain reaction (PCR) for malaria diagnosis and to compare its accuracy with microscopy and an antigen based rapid diagnostic test (OptiMal). STUDY DESIGN: Cross-sectional analytical study. PLACE AND DURATION OF STUDY: Military Hospital, Armed Forces Institute of Transfusion and Armed Forces Institute of Pathology, Rawalpindi, from July to December 2011. METHODOLOGY: Venous blood samples of 300 clinically suspected patients of malaria were tested for malaria parasite by microscopy and OptiMal; and malaria parasite index was calculated for the positive samples. Plasmodium genus specific real time PCR was performed on all specimens, targeting small subunit rRNA gene. Diagnostic accuracy of three tests was compared and cost analysis was done. RESULTS: Out of 300 patients, malaria parasite was detected in 110, 106 and 123 patients by microscopy, OptiMAL and PCR respectively. Real time PCR was 100% sensitive while microscopy and OptiMal had sensitivity of 89.4% and 86.2% respectively. All methods were 100% specific. The cost per test was calculated to be 0.2, 2.75 and 3.30 US$ by microscopy, OptiMal and PCR respectively, excluding the once capital cost on PCR equipment. CONCLUSION: Genus specific real time PCR for the diagnosis of malaria was successfully established as a highly sensitive and affordable technology that should be incorporated in the diagnostic algorithm in this country.
Publication Details
Page(s) 787-792
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 23, Issue: 11, Year: 2013

Request the full text from PASTIC

0

Citations

0

Downloads

78

Views