No Detail Found!

High-Performance Liquid Chromatographic quantification of rifampicin in human plasma: Method for therapeutic drug monitoring.

Author(s)
Trabelsi Sameh Laboratory of Clinical Pharmacology, National Centre of Pharmacovigilance, 9, Avenue Dr. Zouheir Essafi, 1006, Tunis, Tunisia; Faculty of Medicine, El Manar University, Tunis, Tunisia
Eljebari Hanene Laboratory of Clinical Pharmacology, National Centre of Pharmacovigilance, 9, Avenue Dr. Zouheir Essafi, 1006, Tunis, Tunisia
Charfi Rim Laboratory of Clinical Pharmacology, National Centre of Pharmacovigilance, 9, Avenue Dr. Zouheir Essafi, 1006, Tunis, Tunisia;Faculty of Medicine, El Manar University, Tunis, Tunisia
Salouage Issam Laboratory of Clinical Pharmacology, National Centre of Pharmacovigilance, 9, Avenue Dr. Zouheir Essafi, 1006, Tunis, Tunisia
Gaïes Emna Laboratory of Clinical Pharmacology, National Centre of Pharmacovigilance, 9, Avenue Dr. Zouheir Essafi, 1006, Tunis, Tunisia;Faculty of Medicine, El Manar University, Tunis, Tunisia
Nadia Jebabli Laboratory of Clinical Pharmacology, National Centre of Pharmacovigilance, 9, Avenue Dr. Zouheir Essafi, 1006, Tunis, Tunisia
Lakhal Mohamed Laboratory of Clinical Pharmacology, National Centre of Pharmacovigilance, 9, Avenue Dr. Zouheir Essafi, 1006, Tunis, Tunisia
Klouz Anis Laboratory of Clinical Pharmacology, National Centre of Pharmacovigilance, 9, Avenue Dr. Zouheir Essafi, 1006, Tunis, Tunisia;Faculty of Medicine, El Manar University, Tunis, Tunisia
Abstract
A high performance liquid chromatography (HPLC) method has been developed that allows quantification of Rifampicin in human plasma. The method is based on the precipitation of proteins in human plasma with methanol. Optimal assay conditions were found with a C18 column and a simple mobile phase consisting of 0.05 M dipotassic hydrogen phosphate buffer and acetonitrile (53/47, V/V) with 0.086 % diethylamin, pH = 4.46. The flow-rate was 0.6 mL/min and the drug was monitored at 340 nm. Results from the HPLC analyses showed that the assay method is linear in the concentration range of 1-40 µg/mL (r² >0.99). The limit of quantification and limit of detection of Rifampicin were 0.632 µg/mL and 0.208 µg/mL, respectively. Intraday and interday coefficient of variation and bias were below 10% for all samples, suggesting good precision and accuracy of the method. Recoveries were greater than 90% in a plasma sample volume of 100 µL. The method is being successfully applied to therapeutic drug monitoring of Rifampicin in plasma samples of tuberculosis and staphylococcal infections patients.
Publication Details
Page(s) 29-35
DOI DOI not available
Published Journal: Pakistan Journal of Scientific and Industrial Research Series B: Biological Sciences, Volume: 56, Issue: 1, Year: 2013

Request the full text from PASTIC

0

Citations

0

Downloads

73

Views