Separation and determination of Chromium (III) Chromium (VI), gold (III) and arsenic (V) by capillary zone Electrophoresis using 2-Acetylpyridine-4-Phenylthiosemicarbazone as complexing reagent.

Author(s)
Arfana Mallah Dr. M. A. Kazi Institute of Chemistry, University of Sindh, Jamshoro, Pakistan
Saima Qayyummemon Dr. M. A. Kazi Institute of Chemistry, University of Sindh, Jamshoro, Pakistan
Amber Rehana Solangi Dr. M. A. Kazi Institute of Chemistry, University of Sindh, Jamshoro, Pakistan; National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, Pakistan
Abdullah Khan Department of Chemistry, University of Baluchistan, Quetta, Pakistan
Muhammad Yar Khuhawar Institute of Advance Research Studies in Chemical Sciences, University of Sindh, Jamshoro, Pakistan
Muhammad Iqbal Bhanger HEJ Research Institute of Chemistry, International Centre for Chemical and Biological Sciences (ICCBS), University of Karachi, Karachi, Pakistan
Abstract
Capillary zone electrophoretic procedure has been developed for the speciation of Cr (III) and Cr (VI) along with separation from Au (III) and As (V) as chelate compounds of 2-acetylpyridine-4-phenylthiosemicarbazone (APPT). APPT reacts with Cr (III), Cr (VI), Au (III) and As (V) to form water-methanol soluble chelates which absorb maximally within 360 - 418 nm with molar absorptivity of 3.2 × 103to 1.2×104L mol-1cm-1. Off line pre-capillary complexes of the cations prepared were introduced onto uncoated fused silica capillary of 54 cm effective length with 75 µm id by auto-sampler and separated with background electrolyte (BGE) system of oxalate buffer at pH-4 at an applied voltage of +15 kV. Photodiode array detection was carried out at 241 nm. Linear calibrations were obtained within 1-80 µgmL-1 for all the cations. The separation and quantitation was repeatable in terms of migration time and peak height with relative standard deviation (RSD) within 2% (n=4). The limit of detection (LOD) measured were 0.125 µgmL-1, 1.0 µgmL-1, 0.2 µgmL-1 and 0.1 respectively for Au(III), As(V), Cr (III) and Cr(VI). The limits of quantitation (LOQ) were in the range of 0.375- 3.0 µgmL-1. The method was applied for the determination of Cr (III) from tap water, Cr (VI) from industrial effluents and Au (III) and As (V) from pore water of coal mines with RSD within 4%. The results of analysis were supported by standard addition method and rechecked by atomic absorption spectrometry (AAS).
Publication Details
Page(s) 255-262
DOI DOI not available
Published Journal: Journal of Chemical Society of Pakistan, Volume: 36, Issue: 2, Year: 2014