To study radon concentration, exhalation rate and its dependence on grain size, soil samples were collected from different locations in Kedah, Malaysia. These samples were dried, ground and passed though different sieves in order to get different grain sizes. Radon exhalation rate and its dependence on grain size were measured by Continuous Radon Monitor (model, 1029). The average values of radon exhalation rate for all samples were found 4.1±0.26, 5.1±0.33 and 6.1±0.40 Bq m-2 h-1 with grain sizes of 0.249, 0.500 and 1.00 mm, respectively. The results show that radon exhalation rate increases with increase in grain size. The estimated values of radon exhalation rates for all samples were found to be lower than the international accepted value 57.60 Bq m-2 h-1.