A comparative analysis of the Baska® Mask vs. Proseal® laryngeal mask for general anesthesia with IPPV.

Author(s)
Sharifa Ali Sabeeh Al-Rawahi Anesthesiology & Intensive Care, National Trauma Centre, Khoula Hospital, Muscat, Oman
Haris Aziz Anesthesiology & Intensive Care, National Trauma Centre, Khoula Hospital, Muscat, Oman
Azharuddin M Malik Department of Medicine, J N Medical College, Aligarh India
Rashid M Khan Anesthesiology & Intensive Care, National Trauma Centre, Khoula Hospital, Muscat, Oman
Naresh Kaul Anesthesiology & Intensive Care, National Trauma Centre, Khoula Hospital, Muscat, Oman
Abstract
Objective: To compare the sealing pressure of the Baska® Mask (BM) with Proseal® laryngeal mask (PLM) in patients undergoing general anesthesia for a variety of elective non-head and neck surgical procedures. Design: Prospective, randomized, ethical issues committee approved interventional study. Setting: Operating rooms of Khoula Hospital, Muscat (Oman). Methodology: 52 consecutive adult patients of either sex requiring general anesthesia were included in the study. Patients with BMI >30, having known tendency to nausea/vomiting or pharyngeal pathology were excluded from the study. Following uniform induction with propofol 2-2.5 mg/kg, fentanyl 1.0-1.5 μg/kg, and relaxation with cisatracurium 0.1 mg/kg, either BM (n= 30) or PLM (n= 22) was placed. Primary outcome measure was airway seal pressure while secondary outcome measures included device insertion time, number of attempts, leak fraction, duration of use, and laryngopharyngeal morbidity (sore throat, dysphagia, and dysphonia) at 1 hour and 4 hours postoperatively. Data collection was done by a staff member not involved with the study. Results: The mean insertion time was significantly shorter in the BM group as compared to the PLM group (16.43 ± 4.54 vs. 21.45 ± 6.13)(P=0.001). Mean sealing pressure was significantly higher in the BM group (29.98 ± 8.51 vs. 24.50 ± 6.19)(p= 0.013). The leak fraction showed no difference between the devices and it ranged from 5.5-20% and 5-20% in the BM and PLM group respectively. All other studied parameters showed insignificant differences between the two devices. Conclusion: BM takes significantly shorter placement time and provides a better seal as compared to PLM.
Publication Details
Page(s) 233-236
DOI DOI not available
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 17, Issue: 3, Year: 2013

Request the full text from PASTIC

0

Citations

0

Downloads

190

Views