The purpose of this in vitro study was to compare the microleakage of occlusal resin composite and three glass ionomer/ resin composite techniques. Class I occlusal preparations were initiated on forty molar teeth. Teeth were randomly assigned tofour groups of ten. Groups were restored as follow: 1) Solo Plus Point 4 resin composite, 2) Fuji IX/ Fuji Bond LC/ Point 4, 3) Fuji IX/ Experimental Liquid-Liquid glass ionomer bonding material / Point 4, 4) Fuji IX/ Solo Plus / Point 4. After 24 hours storage in distilled water at 37°C, the restoration was subjected to 2500 thermal cycles between 8°C and 48°C with a 30 second dwell time and 10-second transit time. They were placed in a 5% aqueous solution of methylene blue dye for 18 hours. Then, the teeth were sectioned bucco-lingually for microleakage assessment. Results were analyzed using a Kruskal- Wallis One-way ANOVA and Tukey All Pairwise Multiple Comparison procedures. Results showed the glass ionomer/ resin composite treatment groups lined with an experimental liquid-liquid glass ionomer showed significantly less leakage than the resin composite group at p