The behaviour of FRP structural profiles loaded in compression (e.g., column) has been investigated experimentally. Pin-ended columns of varying heights, taken from 51 x 5I X 3.5mm and 44 x 44 x 6.0mm GRP box-section profiles have been axially loaded. Ultimate loads and failure modes have been observed. Long composite columns buckled globally in a fashion similar to isotropic (metallic) columns. Measured and predicted (using Euler formula) buckling loads are in good agreement. Short columns exhibited local flange buckling followed by breaking and tearing of web interfaces. Thicker sections showed material failure at the loading edges at stresses nearly half of the material’s ultimate compressive stress. Interaction between global and local modes has been observed in intermediate range of column heights. Model interaction has been found Sensitive to material and dimensional imperfections. A universal design curve has been drawn using experimentally measured buckling or failure loads for long, intermediate and short columns. Theoretical loads have been predicted using conventional elastic theory (Euler and orthotropic plate buckling approaches) and used for the construction of design curve. Slenderness ratio for the FRP columns has been defined as function of column height, minimum short column load and material and cross-sectional properties. An interaction coefficient, indicating the amount of interaction between the two isolated modes (global and local) has been graphically estimated using experimental and theoretical loads. The design curve represents all the practical heights of the FRP columns.