Evaluation of pFAST for assessment of left ventricular volumes and ejection fraction: Comparison with ERNA and QGS.

Author(s)
Mohammad Ayub Punjab Institute of Cardiology, Jail Road Lahore, Pakistan
Aamir Javaid Punjab Institute of Cardiology, Jail Road Lahore, Pakistan
Ajmal Khursheed Punjab Institute of Cardiology, Jail Road Lahore, Pakistan
Mohammad Azhar Punjab Institute of Cardiology, Jail Road Lahore, Pakistan
Abstract
Gated SPECT is widely used for assessment of myocardial perfusion and function. Various algorithms are available for quantification of gated SPECT for assessment of LV function parameters. QGS has been extensively tested and validated with ERNA and angiographic data pFAST is a new PC based package for quantitative gated SPECT display, analysis and report generating but still requires validation. This study is designed to evaluate pFAST algorithm for determination of left ventricular ejection fraction (EF), end diastolic volume (EDV) and end systolic volume (ESV) and compare the results with those of equilibrium radionucleide angiography (ERNA) and quantitative gated SPECT (QFS). Fifty known coronary artery disease patients(28M, 22F) were enrolled for the study. All patients underwent resting gated myocardial perfusion SPECT with Tc 99m sestamibi and ERNA on his separate days on prism 2000XP gamma camputer inferfrced with Oddyssey VP camputer. Gated SPECT data were acquired in 64 x 64 matrix over 180 degrees in step and shoot manner at 8 frames per cycle. ERNA data were acquired in standard LAO projection at 24 frames per cycle. Gated myocardial perfusion data were reconstructed into trans axial slices using a ramp filter. A 3D low pass filter of order 5.0 and cutoff frequency 0.21 was applied and slices were reoriented into short axis slices were converted to DICOM format and transferred to PC over LAN for processing with pFAST software. The results of ERNA, QGS and pFAST were compared with respect to EF, EDY and ESV. Excellent correlation was found between EF measured with pFAST and ERNA (y=0.9351. r2 =0.8012), pFAST and QGS (y=0.9594, r2 =0.8125). ESV and EDV volumes measured with pFAST also correlated with those of ERNA and QGS. However, pFAST overestimated EDV by 23% compated with ERNA and by 38% compare with QGS. Similarly pFAST overestimated ESV by 35% compared with ERNA and by 41% compared with QGS. pFAST is highly reliable for assessment of EF but it overestimates left ventricular volumes.
Publication Details
Page(s) 11-14
DOI DOI not available
Published Journal: Journal of Cardiovascular Diseases, Volume: 2, Issue: 1, Year: 2004

Request the full text from PASTIC

0

Citations

0

Downloads

81

Views